Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,948

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0096 # 09 Y:2005 09 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $175 $0 Not Implemented
BD0288 # 01 Y:2005 01 2005 INSTALL REPLACEMENT DOORS $65,227 $72,000 Implemented
BD0288 # 02 Y:2005 02 2005 USE RADIANT HEATER FOR SPOT HEATING $13,106 $12,800 Not Implemented
BD0288 # 03 Y:2005 03 2005 REPLACE BOILER $14,342 $2,500 Implemented
BD0288 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,812 $900 Implemented
BD0288 # 05 Y:2005 05 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $5,194 $2,000 Implemented
BD0288 # 06 Y:2005 06 2005 USE SYNTHETIC LUBRICANT $536 $550 Implemented
BD0288 # 07 Y:2005 07 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,293 $10,160 Implemented
BD0288 # 08 Y:2005 08 2005 REPAIR AND ELIMINATE STEAM LEAKS $2,844 $2,400 Implemented
BD0288 # 09 Y:2005 09 2005 RECOVER WASTE HEAT FROM EQUIPMENT $712 $1,000 Not Implemented
BD0288 # 10 Y:2005 10 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,050 $300 Implemented
BD0288 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,154 $2,480 Not Implemented
BD0288 # 12 Y:2005 12 2005 INSTALL OCCUPANCY SENSORS $677 $375 Implemented
BD0288 # 13 Y:2005 13 2005 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,651 $1,250 Not Implemented
OK0707 # 01 Y:2005 01 2005 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,316 $7,739 Not Implemented
OK0707 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,571 $25,675 Implemented
OK0707 # 03 Y:2005 03 2005 INSTALL SET-BACK TIMERS $4,532 $1,380 Not Implemented
OK0707 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,916 $617 Not Implemented
OK0707 # 05 Y:2005 05 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,639 $6,750 Implemented
OK0707 # 06 Y:2005 06 2005 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,173 $6,405 Not Implemented
OK0707 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $594 $626 Not Implemented
BD0284 # 01 Y:2005 01 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,372 $800 Implemented
BD0284 # 02 Y:2005 02 2005 USE SYNTHETIC LUBRICANT $7,827 $2,200 Not Implemented
BD0284 # 03 Y:2005 03 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,583 $18,820 Implemented
BD0284 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,801 $1,464 Implemented