Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
179
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0256 # 02 Y:2007 | 02 | 2007 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $15,602 | $5,000 | Not Implemented |
LE0256 # 01 Y:2007 | 01 | 2007 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $101,767 | $50,000 | Not Implemented |
LE0256 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $689 | $500 | Not Implemented |
LE0256 # 08 Y:2007 | 08 | 2007 | INSTALL OCCUPANCY SENSORS | $1,207 | $1,200 | Not Implemented |
LE0256 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,990 | $11,733 | Not Implemented |
LE0256 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,536 | $15,000 | Not Implemented |
LE0256 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $4,138 | $5,000 | Not Implemented |
LE0256 # 04 Y:2007 | 04 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,965 | $35,200 | Implemented |
LE0195 # 11 Y:2004 | 11 | 2004 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $960 | $200 | Implemented |
LE0195 # 09 Y:2004 | 09 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,529 | $12,960 | Not Implemented |
LE0195 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $33,048 | $40,000 | Not Implemented |
LE0195 # 02 Y:2004 | 02 | 2004 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $29,156 | $14,088 | Not Implemented |
LE0195 # 01 Y:2004 | 01 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $575,674 | $984,000 | Not Implemented |
LE0195 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,168 | $6,683 | Implemented |
LE0195 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,095 | $0 | Implemented |
LE0195 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,604 | $40,000 | Not Implemented |
LE0195 # 04 Y:2004 | 04 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,946 | $48,000 | Implemented |
LE0195 # 08 Y:2004 | 08 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,089 | $0 | Implemented |
LE0195 # 10 Y:2004 | 10 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,299 | $1,200 | Implemented |
HO0205 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,560 | $11,408 | Implemented |
HO0205 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,069 | $0 | Implemented |
HO0205 # 05 Y:1999 | 05 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,237 | $833 | Not Implemented |
HO0205 # 06 Y:1999 | 06 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,015 | $27,500 | Not Implemented |
HO0205 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,757 | $5,030 | Implemented |
HO0205 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,922 | $12,583 | Not Implemented |