Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
211
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0024 # 05 Y:2008 | 05 | 2008 | $2,166 | $1,324 | Not Implemented | |
TT0024 # 03 Y:2008 | 03 | 2008 | $5,947 | $6,703 | Not Implemented | |
GT0761 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,569 | $661 | Not Implemented |
GT0761 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,599 | $750 | Implemented |
GT0761 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,100 | $2,400 | Implemented |
GT0761 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,317 | $66,467 | Implemented |
GT0761 # 02 Y:2003 | 02 | 2003 | USE SYNTHETIC LUBRICANT | $1,449 | $0 | Implemented |
GT0761 # 09 Y:2003 | 09 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,960 | $0 | Not Implemented |
GT0761 # 01 Y:2003 | 01 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,163 | $0 | Not Implemented |
GT0761 # 05 Y:2003 | 05 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $1,540 | $300 | Implemented |
GT0761 # 04 Y:2003 | 04 | 2003 | INSULATE FEEDWATER TANK | $1,440 | $189 | Implemented |
MS0220 # 08 Y:2003 | 08 | 2003 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $11,759 | $3,266 | Not Implemented |
MS0220 # 07 Y:2003 | 07 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $462 | $708 | Not Implemented |
MS0220 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $1,395 | $1,350 | Not Implemented |
MS0220 # 01 Y:2003 | 01 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $118,492 | $100 | Implemented |
MS0220 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,922 | $2,070 | Not Implemented |
MS0220 # 03 Y:2003 | 03 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $2,495 | $600 | Not Implemented |
MS0220 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,427 | $501 | Not Implemented |
MS0220 # 05 Y:2003 | 05 | 2003 | DISCONNECT BALLASTS | $1,708 | $1,602 | Not Implemented |
MS0206 # 14 Y:2002 | 14 | 2002 | BURN WASTE OIL FOR HEAT | $3,807 | $5,761 | n/a |
MS0206 # 02 Y:2002 | 02 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,945 | $8,000 | n/a |
MS0206 # 12 Y:2002 | 12 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $257 | $250 | n/a |
MS0206 # 01 Y:2002 | 01 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,045 | $7,508 | n/a |
MS0206 # 05 Y:2002 | 05 | 2002 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $5,141 | $971 | n/a |
MS0206 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,335 | $189 | n/a |