Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0168 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,736 | $7,712 | Implemented |
SD0168 # 05 Y:1997 | 05 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,294 | $2,680 | Implemented |
SD0168 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $1,610 | $943 | Implemented |
SD0168 # 07 Y:1997 | 07 | 1997 | CONVERT TO LESS TOXIC HYDROCARBON CLEANERS | $6,476 | $0 | Not Implemented |
SD0168 # 08 Y:1997 | 08 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,960 | $9,000 | Implemented |
SD0168 # 09 Y:1997 | 09 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $15,600 | $9,000 | Implemented |
AS0200 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,061 | $18,500 | Not Implemented |
AS0200 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,941 | $17 | Not Implemented |
AS0200 # 03 Y:1997 | 03 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $1,567 | $1,440 | Implemented |
AS0200 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,154 | $224 | Implemented |
AS0200 # 05 Y:1997 | 05 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $464 | $621 | Implemented |
AS0200 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $313 | $300 | Not Implemented |
AS0200 # 07 Y:1997 | 07 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,346 | $14,000 | Implemented |
AS0200 # 08 Y:1997 | 08 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,344 | $34 | Not Implemented |
AS0200 # 09 Y:1997 | 09 | 1997 | ELIMINATE SHIFT | $26,201 | $100 | Implemented |
SF0112 # 01 Y:1997 | 01 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,440 | $12,207 | n/a |
SF0112 # 02 Y:1997 | 02 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $494 | $663 | n/a |
SF0112 # 03 Y:1997 | 03 | 1997 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $223 | $88 | n/a |
SF0112 # 04 Y:1997 | 04 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $16,103 | $4,704 | n/a |
SF0112 # 05 Y:1997 | 05 | 1997 | METER WASTE WATER | $69,902 | $60,000 | n/a |
HO0150 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,148 | $31,658 | Not Implemented |
HO0150 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $791 | $700 | Implemented |
HO0150 # 03 Y:1997 | 03 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $413 | $310 | Implemented |
HO0150 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,566 | $60 | Not Implemented |
HO0150 # 05 Y:1997 | 05 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,000 | $6,500 | Not Implemented |