Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0106 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,304 | $770 | Not Implemented |
NC0106 # 04 Y:1997 | 04 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,634 | $1,200 | Implemented |
NC0106 # 05 Y:1997 | 05 | 1997 | REDUCE VENTILATION AIR | $21,825 | $35,000 | Implemented |
NC0106 # 06 Y:1997 | 06 | 1997 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,895 | $0 | Not Implemented |
NC0106 # 07 Y:1997 | 07 | 1997 | USE PHOTOCELL CONTROLS | $113 | $90 | Implemented |
NC0106 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $507 | $1,530 | Not Implemented |
NC0106 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $193 | $840 | Not Implemented |
NC0106 # 10 Y:1997 | 10 | 1997 | REDUCE SCRAP PRODUCTION | $187,277 | $0 | Not Implemented |
NC0106 # 11 Y:1997 | 11 | 1997 | REDUCE SCRAP PRODUCTION | $38,000 | $0 | Implemented |
OK0513 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,003 | $1,048 | Implemented |
OK0513 # 02 Y:1997 | 02 | 1997 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,233 | $343 | Implemented |
OK0513 # 03 Y:1997 | 03 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $27,432 | $3,300 | Implemented |
OK0513 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,204 | $5,551 | Not Implemented |
OK0513 # 05 Y:1997 | 05 | 1997 | INSTALL SET-BACK TIMERS | $331 | $126 | Not Implemented |
OK0513 # 06 Y:1997 | 06 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,859 | $0 | Not Implemented |
OK0513 # 07 Y:1997 | 07 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,226 | $9,259 | Not Implemented |
OK0513 # 08 Y:1997 | 08 | 1997 | RECYCLE WHITE WATER | $729,526 | $4,000,000 | Not Implemented |
OK0513 # 09 Y:1997 | 09 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $46,860 | $72,000 | Implemented |
GT0597 # 01 Y:1996 | 01 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $9,934 | $5,000 | Not Implemented |
GT0597 # 02 Y:1996 | 02 | 1996 | OPERATE BOILERS ON HIGH FIRE SETTING | $8,380 | $2,000 | Not Implemented |
GT0597 # 03 Y:1996 | 03 | 1996 | MINIMIZE WATER USAGE | $62,640 | $0 | Not Implemented |
GT0597 # 04 Y:1996 | 04 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,570 | $75,450 | Not Implemented |
GT0597 # 05 Y:1996 | 05 | 1996 | INSTALL COMMON HEADER ON COMPRESSORS | $29,270 | $96,000 | Not Implemented |
GT0597 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,760 | $48,450 | Not Implemented |
NC0097 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,021 | $2,451 | Not Implemented |