Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0449 # 09 Y:1994 | 09 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $241 | Implemented |
IA0100 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,713 | $30,600 | Implemented |
IA0100 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,463 | $6,309 | Implemented |
IA0100 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $2,587 | $1,694 | Implemented |
IA0100 # 04 Y:1994 | 04 | 1994 | USE PHOTOCELL CONTROLS | $1,545 | $600 | Implemented |
IA0100 # 05 Y:1994 | 05 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,490 | $175 | Implemented |
IA0100 # 06 Y:1994 | 06 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,837 | $100 | Not Implemented |
IA0100 # 07 Y:1994 | 07 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,274 | $1,680 | Implemented |
IA0100 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,056 | $12,220 | Implemented |
IA0100 # 09 Y:1994 | 09 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,880 | $5,000 | Implemented |
IA0100 # 10 Y:1994 | 10 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $761 | $475 | Implemented |
IA0100 # 11 Y:1994 | 11 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,016 | $250 | Not Implemented |
ME0145 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,797 | $300 | Implemented |
ME0145 # 02 Y:1994 | 02 | 1994 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $1,471 | $800 | Not Implemented |
ME0145 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $827 | $85 | Not Implemented |
ME0145 # 04 Y:1994 | 04 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $642 | $550 | Not Implemented |
BD0013 # 01 Y:1994 | 01 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,745 | $2,250 | Not Implemented |
BD0013 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,926 | $100 | Not Implemented |
BD0013 # 03 Y:1994 | 03 | 1994 | RECOVER AND REUSE COOLING WATER | $1,975 | $5,000 | Not Implemented |
BD0013 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,553 | $13,640 | Not Implemented |
BD0013 # 05 Y:1994 | 05 | 1994 | INSTALL TURBULATORS | $1,003 | $2,400 | Not Implemented |
BD0013 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,835 | $13,008 | Not Implemented |
OD0014 # 01 Y:1994 | 01 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $760 | $1,242 | Implemented |
OD0014 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,974 | $4,176 | Not Implemented |
OD0014 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,646 | $800 | Implemented |