Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,012
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0400 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,700 | $41,732 | Not Implemented |
SF0400 # 10 Y:2011 | 10 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $23,990 | $67,329 | Not Implemented |
SF0400 # 11 Y:2011 | 11 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $31,158 | $170,718 | Not Implemented |
SF0400 # 12 Y:2011 | 12 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $171,695 | $1,807,809 | Not Implemented |
MZ0064 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,083 | $6,900 | Implemented |
MZ0064 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58,225 | $57,800 | Implemented |
MZ0064 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $12,142 | $3,680 | Implemented |
MZ0064 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $1,520 | $8,600 | Implemented |
MZ0064 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,258 | $1,800 | Implemented |
MZ0064 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,612 | $0 | Implemented |
OK0810 # 01 Y:2011 | 01 | 2011 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $41,808 | $12,400 | Not Implemented |
OK0810 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $44,840 | $11,400 | Implemented |
OK0810 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,360 | $14,062 | Not Implemented |
OK0810 # 04 Y:2011 | 04 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,317 | $0 | Implemented |
OK0810 # 05 Y:2011 | 05 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,915 | $0 | Not Implemented |
DL0070 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $136,635 | $120,000 | Implemented |
DL0070 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $12,200 | $200 | Implemented |
DL0070 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $2,160 | $45 | Not Implemented |
DL0070 # 04 Y:2011 | 04 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $14,330 | $500 | Implemented |
DL0070 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,782 | $1,800 | Not Implemented |
DL0070 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $104,177 | $157,000 | Implemented |
DL0070 # 07 Y:2011 | 07 | 2011 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $4,600 | $10,000 | Not Implemented |
DL0070 # 08 Y:2011 | 08 | 2011 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $21,528 | $52,000 | Implemented |
DL0070 # 09 Y:2011 | 09 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,701 | $10,500 | Not Implemented |
DL0070 # 10 Y:2011 | 10 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $33,730 | $1,035,000 | Not Implemented |