Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
521
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0590 # 04 Y:2019 | 04 | 2019 | INSTALL OCCUPANCY SENSORS | $319 | $585 | Implemented |
SD0590 # 01 Y:2019 | 01 | 2019 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $12,001 | $8,840 | Not Implemented |
SD0590 # 03 Y:2019 | 03 | 2019 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $880 | $120 | Implemented |
SD0590 # 02 Y:2019 | 02 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,948 | $0 | Implemented |
SD0566 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,548 | $4,000 | Implemented |
SD0566 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,996 | $72,976 | Implemented |
SD0566 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,929 | $1,200 | Not Implemented |
SD0566 # 03 Y:2018 | 03 | 2018 | USE PHOTOCELL CONTROLS | $13,413 | $3,068 | Implemented |
SD0566 # 01 Y:2018 | 01 | 2018 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $100,744 | $336,960 | Implemented |
SD0566 # 06 Y:2018 | 06 | 2018 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,156 | $5,358 | Implemented |
SF0512 # 06 Y:2018 | 06 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $50,506 | $343,102 | Not Implemented |
SF0512 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,202 | $9,352 | Implemented |
SF0512 # 04 Y:2018 | 04 | 2018 | INSULATE BARE EQUIPMENT | $118 | $389 | Implemented |
SF0512 # 01 Y:2018 | 01 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,199 | $0 | Implemented |
SF0512 # 05 Y:2018 | 05 | 2018 | INSTALL OCCUPANCY SENSORS | $6,777 | $31,273 | Implemented |
SF0512 # 02 Y:2018 | 02 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,566 | $698 | Implemented |
SD0510 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $10,167 | $7,660 | Implemented |
SD0510 # 06 Y:2015 | 06 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,002 | $500 | Not Implemented |
SD0510 # 01 Y:2015 | 01 | 2015 | REDUCE SCRAP PRODUCTION | $19,598 | $28,920 | Implemented |
SD0510 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,415 | $13,500 | Not Implemented |
SD0510 # 03 Y:2015 | 03 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,931 | $9,450 | Implemented |
SD0510 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,778 | $864 | Implemented |
SD0498 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,814 | $500 | Implemented |
SD0498 # 05 Y:2015 | 05 | 2015 | INCREASE AMOUNT OF CONDENSATE RETURNED | $3,194 | $8,000 | Implemented |
SD0498 # 03 Y:2015 | 03 | 2015 | REDUCE EXCESS STEAM BLEEDING | $10,701 | $14,842 | Not Implemented |