Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
512
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0232 # 04 Y:2002 | 04 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,291 | $1,460 | Not Implemented |
SF0232 # 08 Y:2002 | 08 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,509 | $0 | Not Implemented |
SF0232 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $300 | $294 | Not Implemented |
SF0232 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $870 | $2,355 | Not Implemented |
SF0232 # 07 Y:2002 | 07 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,485 | $0 | Not Implemented |
SF0232 # 02 Y:2002 | 02 | 2002 | INCREASE AMOUNT OF CONDENSATE RETURNED | $443 | $325 | Not Implemented |
SF0232 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,269 | $0 | Implemented |
SF0232 # 05 Y:2002 | 05 | 2002 | USE PHOTOCELL CONTROLS | $501 | $1,080 | Not Implemented |
AS0340 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,051 | $30 | Not Implemented |
AS0340 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,113 | $5,518 | Implemented |
AS0340 # 07 Y:2002 | 07 | 2002 | USE SYNTHETIC LUBRICANT | $13,263 | $6,971 | Not Implemented |
AS0340 # 08 Y:2002 | 08 | 2002 | OPTIMIZE PLANT POWER FACTOR | $6,618 | $1,590 | Not Implemented |
AS0340 # 09 Y:2002 | 09 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $73,135 | $13,732 | Not Implemented |
AS0340 # 10 Y:2002 | 10 | 2002 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $5,400 | $8,554 | Not Implemented |
AS0340 # 11 Y:2002 | 11 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $25,624 | $4,800 | Implemented |
AS0340 # 12 Y:2002 | 12 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $32,500 | $6,000 | Not Implemented |
AS0340 # 13 Y:2002 | 13 | 2002 | CLEAR AND RENT EXISTING SPACE | $60,660 | $8,804 | Implemented |
AS0340 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $155 | $20 | Implemented |
AS0340 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,190 | $0 | Not Implemented |
AS0340 # 03 Y:2002 | 03 | 2002 | INSTALL SKYLIGHTS | $36,748 | $54,898 | Not Implemented |
AS0340 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $340 | $600 | Not Implemented |
TA0044 # 01 Y:2002 | 01 | 2002 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $114,400 | $0 | Implemented |
TA0044 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $19,880 | $2,455 | Implemented |
TA0044 # 04 Y:2002 | 04 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $9,715 | $72 | Implemented |
TA0044 # 02 Y:2002 | 02 | 2002 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $23,976 | $65,000 | Not Implemented |