Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
97
matching recommendationsSIC | 2621 | Paper Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0465 # 10 Y:2018 | 10 | 2018 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $23,316 | $98,239 | Not Implemented |
SU0465 # 09 Y:2018 | 09 | 2018 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $452 | $1,526 | Not Implemented |
SU0465 # 08 Y:2018 | 08 | 2018 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $146 | $361 | Not Implemented |
SU0465 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $79 | $105 | Not Implemented |
SU0465 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,797 | $5,696 | Implemented |
SU0465 # 05 Y:2018 | 05 | 2018 | INSTALL OCCUPANCY SENSORS | $1,183 | $740 | Implemented |
SU0465 # 04 Y:2018 | 04 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,746 | $1,021 | Not Implemented |
SU0465 # 03 Y:2018 | 03 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,792 | $0 | Not Implemented |
SU0465 # 02 Y:2018 | 02 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,600 | $0 | Implemented |
SU0465 # 01 Y:2018 | 01 | 2018 | PAY BILLS ON TIME TO AVOID LATE FEES | $5,667 | $0 | Implemented |
SU0297 # 02 Y:2010 | 02 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,367 | $0 | Not Implemented |
SU0297 # 11 Y:2010 | 11 | 2010 | UPGRADE OBSOLETE EQUIPMENT | $1,054 | $4,725 | Implemented |
SU0297 # 10 Y:2010 | 10 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,058 | $45,795 | Implemented |
SU0297 # 09 Y:2010 | 09 | 2010 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $314,524 | $658,300 | Not Implemented |
SU0297 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,260 | $650 | Implemented |
SU0297 # 07 Y:2010 | 07 | 2010 | INSTALL OCCUPANCY SENSORS | $5,273 | $2,136 | Not Implemented |
SU0297 # 05 Y:2010 | 05 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $29,835 | $5,275 | Implemented |
SU0297 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $1,997 | $209 | Not Implemented |
SU0297 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $11,458 | $697 | Implemented |
SU0297 # 08 Y:2010 | 08 | 2010 | OPTIMIZE PLANT POWER FACTOR | $18,693 | $24,129 | Implemented |
SU0297 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $30,345 | $0 | Implemented |
SU0257 # 06 Y:2007 | 06 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $323,145 | $79,171 | Implemented |
SU0257 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,261 | $712 | Implemented |
SU0257 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,124 | $1,000 | Implemented |
SU0257 # 01 Y:2007 | 01 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,366 | $0 | Implemented |