IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

49

matching recommendations
Reset
SIC 263 Paperboard Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0288 # 04 Y:2005 04 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,812 $900 Implemented
BD0288 # 05 Y:2005 05 2005 IMPROVE COMBUSTION CONTROL CAPABILITY $5,194 $2,000 Implemented
BD0288 # 06 Y:2005 06 2005 USE SYNTHETIC LUBRICANT $536 $550 Implemented
BD0288 # 07 Y:2005 07 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,293 $10,160 Implemented
BD0288 # 08 Y:2005 08 2005 REPAIR AND ELIMINATE STEAM LEAKS $2,844 $2,400 Implemented
BD0288 # 09 Y:2005 09 2005 RECOVER WASTE HEAT FROM EQUIPMENT $712 $1,000 Not Implemented
BD0288 # 10 Y:2005 10 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,050 $300 Implemented
BD0288 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,154 $2,480 Not Implemented
BD0288 # 12 Y:2005 12 2005 INSTALL OCCUPANCY SENSORS $677 $375 Implemented
BD0288 # 13 Y:2005 13 2005 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $1,651 $1,250 Not Implemented
BD0162 # 07 Y:2000 07 2000 REUSE / RECYCLE/ SELL PAPER PRODUCTS $340 $200 Not Implemented
BD0162 # 06 Y:2000 06 2000 $1,560 $2,000 Implemented
BD0162 # 05 Y:2000 05 2000 USE EVAPORATION TO CONCENTRATE MATERIAL $13,419 $10,000 Implemented
BD0162 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $247 $172 Not Implemented
BD0162 # 03 Y:2000 03 2000 REPAIR AND ELIMINATE STEAM LEAKS $270 $150 Implemented
BD0162 # 02 Y:2000 02 2000 RECOVER WASTE HEAT FROM EQUIPMENT $709 $800 Not Implemented
BD0162 # 01 Y:2000 01 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,293 $14,000 Not Implemented
BD0014 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $2,169 $1,000 Not Implemented
BD0014 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,866 $2,342 Implemented
BD0014 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,150 $500 Implemented
BD0014 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,051 $20 Implemented
BD0014 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $22,398 $33,500 Implemented
BD0014 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,879 $7,000 Not Implemented
BD0014 # 01 Y:1994 01 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $206,117 $508,700 Not Implemented