Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

380

matching recommendations
Reset
SIC 2631 Paperboard Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OD0057 # 01 Y:1996 01 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,833 $500 Implemented
OD0057 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,120 $600 Implemented
OD0057 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,630 $1,950 Implemented
OD0057 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,768 $430 Implemented
OD0057 # 05 Y:1996 05 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,639 $4,232 Not Implemented
OD0057 # 06 Y:1996 06 1996 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $751 $200 Not Implemented
WV0049 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,292 $0 Implemented
WV0049 # 10 Y:1995 10 1995 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $27,456 $65,000 Not Implemented
WV0049 # 09 Y:1995 09 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $14,328 $215 Not Implemented
WV0049 # 08 Y:1995 08 1995 REPAIR AND ELIMINATE STEAM LEAKS $7,654 $600 Not Implemented
WV0049 # 07 Y:1995 07 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,602 $3,440 Not Implemented
WV0049 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $3,841 $7,136 Implemented
WV0049 # 05 Y:1995 05 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,950 $3,400 Implemented
WV0049 # 03 Y:1995 03 1995 USE SYNTHETIC LUBRICANT $482 $0 Implemented
WV0049 # 02 Y:1995 02 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $459 $0 Implemented
WV0049 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,257 $670 Implemented
BD0014 # 01 Y:1994 01 1994 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $206,117 $508,700 Not Implemented
BD0014 # 02 Y:1994 02 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,879 $7,000 Not Implemented
BD0014 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $22,398 $33,500 Implemented
BD0014 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,051 $20 Implemented
BD0014 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,150 $500 Implemented
BD0014 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,866 $2,342 Implemented
BD0014 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $2,169 $1,000 Not Implemented
WV0038 # 04 Y:1994 04 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $81,877 $4,570 Not Implemented
WV0038 # 07 Y:1994 07 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $807 $0 Implemented