Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 2631 | Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0510 # 01 Y:2002 | 01 | 2002 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $16,518 | $13,775 | n/a |
MA0510 # 02 Y:2002 | 02 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $5,976 | $7,800 | Not Implemented |
MA0510 # 03 Y:2002 | 03 | 2002 | COMBINE UTILITY METERS | $2,200 | $6,470 | Not Implemented |
MA0510 # 04 Y:2002 | 04 | 2002 | REDUCE FLUID FLOW RATES | $1,849 | $0 | Implemented |
MA0510 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,619 | $0 | Implemented |
MA0510 # 06 Y:2002 | 06 | 2002 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,604 | $1,792 | Implemented |
MA0510 # 07 Y:2002 | 07 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,382 | $0 | Implemented |
MA0510 # 08 Y:2002 | 08 | 2002 | USE MINIMUM STEAM OPERATING PRESSURE | $960 | $0 | Implemented |
MA0510 # 09 Y:2002 | 09 | 2002 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $750 | $0 | Implemented |
MA0029 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $94 | Not Implemented |
MA0029 # 02 Y:1985 | 02 | 1985 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $17,454 | $9,015 | Not Implemented |
MA0029 # 03 Y:1985 | 03 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,980 | $268 | Not Implemented |
MA0029 # 04 Y:1985 | 04 | 1985 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $636 | $763 | Not Implemented |
MA0029 # 05 Y:1985 | 05 | 1985 | REDUCE FLUID FLOW RATES | $2,655 | $0 | Not Implemented |
MA0029 # 06 Y:1985 | 06 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,968 | $2,000 | Not Implemented |