Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
220
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0114 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,882 | $0 | Implemented |
MI0114 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $28,126 | $1,091 | Not Implemented |
MI0114 # 02 Y:2005 | 02 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $20,574 | $30,050 | Implemented |
MI0114 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,927 | $27,000 | Not Implemented |
MI0114 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $2,983 | $225 | Implemented |
MI0114 # 05 Y:2005 | 05 | 2005 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $9,790 | $4,360 | Implemented |
MI0114 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,392 | $77 | Implemented |
MI0114 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,896 | $1,074 | Implemented |
MI0114 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,521 | $4,628 | Not Implemented |
UF0335 # 01 Y:2004 | 01 | 2004 | ADD AREA LIGHTING SWITCHES | $2,525 | $10,670 | Not Implemented |
UF0335 # 02 Y:2004 | 02 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $44,300 | $205,000 | Not Implemented |
UF0335 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,089 | $41,729 | Implemented |
UF0335 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,790 | $13,573 | Implemented |
UF0335 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,008 | $0 | Not Implemented |
UF0335 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,359 | $376 | Implemented |
UF0335 # 07 Y:2004 | 07 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,237 | $20,000 | Implemented |
MI0061 # 01 Y:2003 | 01 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,497 | $8,673 | Not Implemented |
MI0061 # 06 Y:2003 | 06 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,157 | $147 | Implemented |
MI0061 # 07 Y:2003 | 07 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $27,760 | $2,808 | Not Implemented |
MI0061 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,605 | $169 | Not Implemented |
MI0061 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $974 | $332 | Implemented |
MI0061 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $524 | $111 | Implemented |
MI0061 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,962 | $6 | Implemented |
UF0320 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,604 | $0 | Not Implemented |
UF0320 # 03 Y:2003 | 03 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $1,161 | $225 | Implemented |