Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,540

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0702 # 07 Y:2016 07 2016 INSTALL OCCUPANCY SENSORS $510 $380 Not Implemented
AM0702 # 08 Y:2016 08 2016 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,323 $600 Implemented
AM0702 # 09 Y:2016 09 2016 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $155 $152 Not Implemented
AM0702 # 10 Y:2016 10 2016 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $141 $350 Implemented
DL0150 # 01 Y:2015 01 2015 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $780 $0 Not Implemented
DL0150 # 02 Y:2015 02 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,920 $500 Not Implemented
DL0150 # 03 Y:2015 03 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $760 $560 Not Implemented
DL0150 # 04 Y:2015 04 2015 INSTALL REPLACEMENT DOORS $2,450 $7,800 Not Implemented
DL0150 # 05 Y:2015 05 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,075 $19,740 Not Implemented
DL0150 # 06 Y:2015 06 2015 LOWER CEILING TO REDUCE CONDITIONED SPACE $13,240 $62,400 Not Implemented
DL0150 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,720 $18,100 Not Implemented
DL0150 # 08 Y:2015 08 2015 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $7,020 $58,500 Not Implemented
LE0397 # 01 Y:2015 01 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,085 $4,300 Not Implemented
LE0397 # 02 Y:2015 02 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,221 $10,086 Implemented
LE0397 # 03 Y:2015 03 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,396 $1,000 Implemented
LE0397 # 04 Y:2015 04 2015 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,238 $5,500 Not Implemented
LE0397 # 05 Y:2015 05 2015 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,917 $14,900 Not Implemented
LE0397 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $116 $1,914 Implemented
MZ0181 # 01 Y:2015 01 2015 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,643 $4,000 Not Implemented
MZ0181 # 02 Y:2015 02 2015 ELIMINATE/REDUCE AN OPERATION $419 $0 Not Implemented
MZ0181 # 03 Y:2015 03 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,725 $8,000 Not Implemented
MZ0181 # 04 Y:2015 04 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,719 $0 Implemented
SD0498 # 01 Y:2015 01 2015 REPAIR AND ELIMINATE STEAM LEAKS $14,239 $1,000 Implemented
SD0498 # 02 Y:2015 02 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,048 $21,000 Not Implemented
SD0498 # 03 Y:2015 03 2015 REDUCE EXCESS STEAM BLEEDING $10,701 $14,842 Not Implemented