IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,546

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0158 # 05 Y:1996 05 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,007 $13,149 Implemented
UF0158 # 06 Y:1996 06 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,222 $850 Implemented
UF0158 # 07 Y:1996 07 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $1,712 $5,490 Not Implemented
UF0158 # 08 Y:1996 08 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $22,535 $24,000 Implemented
UF0158 # 09 Y:1996 09 1996 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $2,074 $2,000 Implemented
UD0496 # 01 Y:1996 01 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,040 $1,500 Implemented
UD0496 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,270 $5,000 Not Implemented
UD0496 # 03 Y:1996 03 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,005 $30,000 Not Implemented
UD0496 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $365 $1,720 Implemented
UD0496 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,485 $18,550 Not Implemented
UD0494 # 01 Y:1996 01 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $12,517 $14,000 Implemented
UD0494 # 02 Y:1996 02 1996 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,890 $0 Not Implemented
UD0494 # 03 Y:1996 03 1996 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $12,533 $0 Not Implemented
UD0494 # 04 Y:1996 04 1996 DISCONNECT BALLASTS $1,437 $1,650 Implemented
UD0494 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,632 $12,454 Implemented
UD0494 # 06 Y:1996 06 1996 RECYCLE WASTE INK AND CLEANUP SOLVENT $810 $0 Implemented
WI0267 # 01 Y:1996 01 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $27,762 $8,906 n/a
WI0267 # 02 Y:1996 02 1996 USE SYNTHETIC LUBRICANT $16,841 $0 n/a
WI0267 # 03 Y:1996 03 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,729 $45,000 n/a
WI0267 # 04 Y:1996 04 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $13,635 $39,000 n/a
WI0267 # 05 Y:1996 05 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $9,054 $16,740 n/a
WI0267 # 06 Y:1996 06 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $6,670 $0 n/a
WI0267 # 07 Y:1996 07 1996 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $4,867 $0 n/a
WI0267 # 08 Y:1996 08 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $3,040 $0 n/a
WI0267 # 09 Y:1996 09 1996 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,236 $5,000 n/a