Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

263

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0042 # 05 Y:2014 05 2014 USE SYNTHETIC LUBRICANT $3,625 $2,066 Not Implemented
WM0042 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,162 $9,680 Implemented
WM0042 # 01 Y:2014 01 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,231 $300 Implemented
WM0042 # 02 Y:2014 02 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $734 $288 Not Implemented
WM0042 # 03 Y:2014 03 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $501 $0 Not Implemented
WM0042 # 04 Y:2014 04 2014 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,034 $2,340 Not Implemented
WM0042 # 07 Y:2014 07 2014 INSTALL OCCUPANCY SENSORS $322 $340 Implemented
BD0391 # 05 Y:2011 05 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,045 $1,500 Not Implemented
BD0391 # 02 Y:2011 02 2011 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $15,276 $7,000 Not Implemented
BD0391 # 04 Y:2011 04 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,808 $11,500 Implemented
BD0391 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,439 $7,923 Implemented
BD0391 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $738 $1,000 Implemented
BD0391 # 01 Y:2011 01 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $29,184 $2,500 Implemented
IC0180 # 03 Y:2011 03 2011 DEVELOP A REPAIR/REPLACE POLICY $5,192 $13,100 Not Implemented
IC0180 # 06 Y:2011 06 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $773 $0 Not Implemented
IC0180 # 10 Y:2011 10 2011 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $10,204 $4,209 Not Implemented
IC0180 # 11 Y:2011 11 2011 REPAIR AND ELIMINATE STEAM LEAKS $8,793 $1,000 Not Implemented
IC0180 # 15 Y:2011 15 2011 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $5,752 $0 Not Implemented
IC0180 # 08 Y:2011 08 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,984 $76 Not Implemented
IC0180 # 13 Y:2011 13 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $7,693 $8,950 Not Implemented
IC0180 # 07 Y:2011 07 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,036 $0 Not Implemented
IC0180 # 16 Y:2011 16 2011 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $117 $0 Not Implemented
IC0180 # 12 Y:2011 12 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $7,693 $8,950 Not Implemented
IC0180 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $647 $1 Not Implemented
IC0180 # 02 Y:2011 02 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,738 $4,051 Not Implemented