Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0231 # 02 Y:2006 | 02 | 2006 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $128,263 | $120,000 | Not Implemented |
LE0231 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,942 | $13,500 | Implemented |
LE0231 # 04 Y:2006 | 04 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $26,565 | $51,000 | Implemented |
LE0231 # 05 Y:2006 | 05 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $21,498 | $4,500 | Implemented |
LE0231 # 06 Y:2006 | 06 | 2006 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $17,212 | $12,500 | Implemented |
LE0231 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $16,394 | $13,060 | Not Implemented |
LE0231 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,127 | $400 | Implemented |
LE0231 # 09 Y:2006 | 09 | 2006 | IMPROVE COMBUSTION CONTROL CAPABILITY | $7,881 | $2,500 | Implemented |
LE0231 # 10 Y:2006 | 10 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,915 | $189 | Implemented |
LE0231 # 11 Y:2006 | 11 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,485 | $3,600 | Implemented |
LE0231 # 12 Y:2006 | 12 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,229 | $500 | Not Implemented |
LE0231 # 13 Y:2006 | 13 | 2006 | INSTALL OCCUPANCY SENSORS | $3,076 | $300 | Not Implemented |
LE0142 # 01 Y:2002 | 01 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $20,390 | $42,000 | Not Implemented |
LE0142 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,173 | $10,000 | Not Implemented |
LE0142 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,631 | $1,500 | Implemented |
LE0142 # 04 Y:2002 | 04 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,077 | $1,920 | Not Implemented |
LE0142 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,299 | $750 | Implemented |
LE0142 # 06 Y:2002 | 06 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,033 | $16,000 | Not Implemented |
LE0142 # 07 Y:2002 | 07 | 2002 | USE SYNTHETIC LUBRICANT | $4,719 | $400 | Implemented |
LE0142 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,628 | $0 | Not Implemented |
LE0136 # 01 Y:2002 | 01 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,384 | $1,200 | Not Implemented |
LE0136 # 02 Y:2002 | 02 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $34,475 | $17,000 | Not Implemented |
LE0136 # 03 Y:2002 | 03 | 2002 | RECOVER AND REUSE COOLING WATER | $1,527 | $2,000 | Not Implemented |
LE0136 # 04 Y:2002 | 04 | 2002 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $34,222 | $60,000 | Not Implemented |
LE0136 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,262 | $1,000 | Not Implemented |