IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,531

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0337 # 03 Y:1991 03 1991 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $11,166 $14,400 Not Implemented
KU0337 # 05 Y:1991 05 1991 INSTALL SET-BACK TIMERS $6,059 $3,000 Not Implemented
KU0337 # 06 Y:1991 06 1991 INSULATE BARE EQUIPMENT $3,175 $1,725 Not Implemented
KU0337 # 07 Y:1991 07 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,279 $5,000 Not Implemented
KU0337 # 08 Y:1991 08 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,499 $4,200 Not Implemented
KU0337 # 09 Y:1991 09 1991 DIRECT WARMEST AIR TO COMBUSTION INTAKE $657 $1,000 Not Implemented
KU0337 # 10 Y:1991 10 1991 REPAIR AND ELIMINATE STEAM LEAKS $633 $300 Not Implemented
KU0337 # 11 Y:1991 11 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $514 $100 Not Implemented
MA0206 # 01 Y:1991 01 1991 OPTIMIZE PLANT POWER FACTOR $20,259 $14,186 Implemented
MA0206 # 02 Y:1991 02 1991 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $10,773 $45,415 Implemented
MA0206 # 03 Y:1991 03 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $498 $145 Implemented
MA0206 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $864 $473 Implemented
MA0206 # 05 Y:1991 05 1991 TURN OFF EQUIPMENT WHEN NOT IN USE $742 $0 Implemented
MA0203 # 01 Y:1991 01 1991 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $13,019 $8,029 Implemented
MA0203 # 02 Y:1991 02 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $7,245 $2,182 Implemented
MA0203 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $778 $547 Implemented
MA0203 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,651 $32,018 Implemented
MA0203 # 05 Y:1991 05 1991 INSTALL SET-BACK TIMERS $642 $161 Implemented
RU0098 # 01 Y:1990 01 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,642 $0 Implemented
RU0098 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,589 $196 Implemented
RU0098 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,134 $302 Not Implemented
RU0098 # 04 Y:1990 04 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,244 $0 Implemented
RU0098 # 05 Y:1990 05 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,377 $1,250 Not Implemented
RU0098 # 06 Y:1990 06 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,352 $500 Not Implemented
RU0098 # 07 Y:1990 07 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,437 $6,800 Not Implemented