Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0170 # 11 Y:1985 | 11 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $147 | $20 | Implemented |
KU0170 # 01 Y:1985 | 01 | 1985 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $97,361 | $494,400 | Not Implemented |
KU0170 # 17 Y:1985 | 17 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $551 | $0 | Implemented |
KU0170 # 16 Y:1985 | 16 | 1985 | INSULATE BARE EQUIPMENT | $1,000 | $591 | Implemented |
KU0170 # 15 Y:1985 | 15 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $962 | $400 | Not Implemented |
KU0170 # 14 Y:1985 | 14 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,514 | $1,300 | Implemented |
KU0170 # 13 Y:1985 | 13 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,835 | $300 | Not Implemented |
KU0170 # 12 Y:1985 | 12 | 1985 | INSULATE BARE EQUIPMENT | $2,018 | $800 | Not Implemented |
KU0170 # 10 Y:1985 | 10 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $606 | $300 | Implemented |
KU0170 # 09 Y:1985 | 09 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $735 | $30 | Implemented |
KU0170 # 08 Y:1985 | 08 | 1985 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,764 | $700 | Implemented |
KU0170 # 07 Y:1985 | 07 | 1985 | IMPROVE LUBRICATION PRACTICES | $6,613 | $2,166 | Not Implemented |
KU0170 # 06 Y:1985 | 06 | 1985 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,746 | $1,000 | Implemented |
KU0170 # 05 Y:1985 | 05 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,901 | $6,000 | Implemented |
KU0170 # 04 Y:1985 | 04 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $5,297 | $300 | Implemented |
KU0170 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,755 | $2,656 | Implemented |
KU0170 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $29,255 | $18 | Implemented |
LT0026 # 05 Y:1985 | 05 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $2,460 | $15 | Implemented |
LT0026 # 08 Y:1985 | 08 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,510 | $3,337 | Not Implemented |
LT0026 # 07 Y:1985 | 07 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,208 | $300 | Implemented |
LT0026 # 06 Y:1985 | 06 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,239 | $2,800 | Implemented |
LT0026 # 03 Y:1985 | 03 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,340 | $405 | Implemented |
LT0026 # 02 Y:1985 | 02 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,870 | $11,300 | Implemented |
LT0026 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,318 | $300 | Implemented |
LT0026 # 04 Y:1985 | 04 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,384 | $138 | Implemented |