Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 2657 | Folding Paperboard Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0558 # 01 Y:1995 | 01 | 1995 | INSULATE BARE EQUIPMENT | $4,752 | $700 | Implemented |
TN0558 # 11 Y:1995 | 11 | 1995 | REUSE RAGS UNTIL COMPLETELY SOILED | $6,974 | $0 | Not Implemented |
TN0558 # 10 Y:1995 | 10 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,274 | $13,600 | Implemented |
TN0558 # 09 Y:1995 | 09 | 1995 | PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) | $8,084 | $5,000 | Not Implemented |
TN0558 # 08 Y:1995 | 08 | 1995 | INSTALL DEDICATED MIXING EQUIP TO OPTIMIZE REUSE OF USED RINSEATE & TO PRECLUDE THE NEED FOR INTER-RUN CLEANING | $10,267 | $200 | Not Implemented |
TN0558 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $234 | $217 | Implemented |
TN0558 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $409 | $100 | Not Implemented |
TN0558 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,595 | $2,300 | Not Implemented |
TN0558 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,526 | $885 | Not Implemented |
TN0558 # 03 Y:1995 | 03 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,003 | $0 | Not Implemented |
TN0558 # 02 Y:1995 | 02 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,210 | $26,368 | Not Implemented |
TN0462 # 08 Y:1992 | 08 | 1992 | IMPROVE LUBRICATION PRACTICES | $116 | $0 | Not Implemented |
TN0462 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $271 | $0 | Not Implemented |
TN0462 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,504 | $390 | Not Implemented |
TN0462 # 05 Y:1992 | 05 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $422 | $660 | Not Implemented |
TN0462 # 04 Y:1992 | 04 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,393 | $400 | Not Implemented |
TN0462 # 03 Y:1992 | 03 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $5,076 | $5,335 | Not Implemented |
TN0462 # 02 Y:1992 | 02 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,871 | $5,400 | Not Implemented |
TN0462 # 01 Y:1992 | 01 | 1992 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $12,369 | $9,880 | Not Implemented |
TN0196 # 01 Y:1983 | 01 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,218 | $150 | Not Implemented |
TN0196 # 02 Y:1983 | 02 | 1983 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $47 | $0 | Not Implemented |