Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,101
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0191 # 02 Y:1983 | 02 | 1983 | USE RADIANT HEATER FOR SPOT HEATING | $3,251 | $5,000 | Implemented |
KU0099 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,778 | $2,585 | Implemented |
KU0099 # 02 Y:1983 | 02 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $935 | $2,350 | Implemented |
KU0099 # 03 Y:1983 | 03 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $628 | $660 | Implemented |
KU0099 # 04 Y:1983 | 04 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $544 | $0 | Implemented |
UD0080 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,599 | $1,472 | Not Implemented |
UD0080 # 02 Y:1983 | 02 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,125 | $53,100 | Not Implemented |
UD0080 # 03 Y:1983 | 03 | 1983 | INSTALL STORM WINDOWS AND DOORS | $12,524 | $20,450 | Not Implemented |
UD0080 # 04 Y:1983 | 04 | 1983 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,981 | $7,000 | Not Implemented |
TN0124 # 01 Y:1982 | 01 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $1,715 | $8,360 | Not Implemented |
TN0124 # 02 Y:1982 | 02 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,333 | $1,080 | Not Implemented |
TN0124 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,101 | $11,060 | Not Implemented |
TN0124 # 04 Y:1982 | 04 | 1982 | INSTALL SET-BACK TIMERS | $2,998 | $60 | Not Implemented |
GT0112 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,062 | $2,400 | Implemented |
GT0112 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $973 | $506 | Implemented |
GT0112 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,411 | $5,029 | Implemented |
GT0112 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,125 | $1,500 | Implemented |
GT0112 # 05 Y:1982 | 05 | 1982 | USE OPTIMUM THICKNESS INSULATION | $3,585 | $5,294 | Implemented |
GT0112 # 06 Y:1982 | 06 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,835 | $0 | Implemented |
GT0112 # 07 Y:1982 | 07 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $656 | $0 | Implemented |
GT0112 # 08 Y:1982 | 08 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $27,024 | $31,500 | Implemented |
GT0112 # 09 Y:1982 | 09 | 1982 | BURN WASTE PAPER FOR HEAT | $106,600 | $200,000 | Not Implemented |
TN0111 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,311 | $1,280 | Not Implemented |
TN0111 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $2,960 | $1,000 | Not Implemented |
TN0111 # 03 Y:1982 | 03 | 1982 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $650 | $1,350 | Not Implemented |