Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
134
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0213 # 03 Y:2005 | 03 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,703 | $25,000 | Not Implemented |
LE0213 # 04 Y:2005 | 04 | 2005 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,279 | $368 | Not Implemented |
LE0213 # 05 Y:2005 | 05 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,792 | $1,000 | Implemented |
LE0213 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,694 | $2,000 | Implemented |
LE0213 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $200 | Implemented |
LE0213 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,210 | $53,880 | Implemented |
NC0292 # 01 Y:2004 | 01 | 2004 | MODIFY CURRENT INCENTIVE PROGRAM | $53,200 | $10,376 | n/a |
NC0292 # 02 Y:2004 | 02 | 2004 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $17,751 | $16,000 | n/a |
NC0292 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,368 | $6,692 | n/a |
NC0292 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,211 | $2,738 | n/a |
NC0292 # 05 Y:2004 | 05 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $4,313 | $6,553 | n/a |
NC0292 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,084 | $720 | n/a |
NC0292 # 07 Y:2004 | 07 | 2004 | ADD AREA LIGHTING SWITCHES | $297 | $750 | n/a |
NC0292 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $115 | $100 | n/a |
NC0292 # 09 Y:2004 | 09 | 2004 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $45 | $50 | n/a |
WV0297 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $121,920 | $33,990 | Not Implemented |
WV0297 # 02 Y:2004 | 02 | 2004 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $25,862 | $55,500 | Not Implemented |
WV0297 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,874 | $6,254 | Not Implemented |
WV0297 # 04 Y:2004 | 04 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,905 | $1,326 | Implemented |
WV0297 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,307 | $108 | Implemented |
WV0297 # 06 Y:2004 | 06 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $1,262 | $1,200 | Implemented |
WV0297 # 07 Y:2004 | 07 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,041 | $142 | Implemented |
WV0297 # 08 Y:2004 | 08 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $799 | $1,000 | Implemented |
WV0297 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $793 | $94 | Implemented |
WV0297 # 10 Y:2004 | 10 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $751 | $282 | Not Implemented |