Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0405 # 09 Y:2008 | 09 | 2008 | INSTALL OCCUPANCY SENSORS | $606 | $256 | Implemented |
SD0405 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,411 | $3,110 | Not Implemented |
SD0405 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,436 | $3,324 | Not Implemented |
SD0405 # 06 Y:2008 | 06 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,270 | $4,650 | Not Implemented |
SD0405 # 01 Y:2008 | 01 | 2008 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $117,665 | $1,117,600 | Implemented |
SD0405 # 02 Y:2008 | 02 | 2008 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $62,965 | $69,500 | Implemented |
SD0405 # 03 Y:2008 | 03 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,824 | $22,665 | Implemented |
SD0405 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,507 | $900 | Implemented |
SD0405 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,660 | $4,270 | Implemented |
SD0331 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $643 | $453 | Not Implemented |
SD0331 # 05 Y:2004 | 05 | 2004 | INSTALL AUTOMATIC PACKING EQUIPMENT | $108,200 | $110,000 | Implemented |
SD0331 # 04 Y:2004 | 04 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,220 | $5,000 | Implemented |
SD0331 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $204 | $0 | Not Implemented |
SD0331 # 01 Y:2004 | 01 | 2004 | USE PHOTOCELL CONTROLS | $4,358 | $410 | Not Implemented |
SF0238 # 01 Y:2002 | 01 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $2,857 | $1,370 | Not Implemented |
SF0238 # 02 Y:2002 | 02 | 2002 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $1,602 | $1,165 | Not Implemented |
SF0238 # 03 Y:2002 | 03 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,638 | $2,860 | Not Implemented |
SF0238 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,051 | $12,627 | Not Implemented |
SF0238 # 05 Y:2002 | 05 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,329 | $16,545 | Not Implemented |
SF0202 # 01 Y:2000 | 01 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $698 | $0 | Implemented |
SF0202 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $960 | $600 | Implemented |
SF0202 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,800 | $11,610 | Not Implemented |
SF0202 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $941 | $5,000 | Not Implemented |
SF0202 # 05 Y:2000 | 05 | 2000 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $5,583 | $2,180 | Implemented |
SF0202 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $11,715 | $17,142 | Not Implemented |