Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0121 # 08 Y:1998 | 08 | 1998 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $10,017 | $2,800 | Implemented |
OD0121 # 07 Y:1998 | 07 | 1998 | INSTALL STEAM TRAP | $1,445 | $560 | Not Implemented |
OD0121 # 06 Y:1998 | 06 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,833 | $1,495 | Implemented |
OD0121 # 05 Y:1998 | 05 | 1998 | REPAIR OR REPLACE STEAM TRAPS | $672 | $110 | Implemented |
OD0121 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $365 | $220 | Implemented |
OD0121 # 03 Y:1998 | 03 | 1998 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $241 | $420 | Implemented |
OD0121 # 02 Y:1998 | 02 | 1998 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $3,843 | $9,910 | Not Implemented |
OD0121 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,192 | $6,908 | Implemented |
AM0331 # 02 Y:1998 | 02 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $14,175 | $7,087 | Implemented |
AM0331 # 13 Y:1998 | 13 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $180 | $0 | Implemented |
AM0331 # 12 Y:1998 | 12 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $460 | $0 | Implemented |
AM0331 # 10 Y:1998 | 10 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $640 | $0 | Implemented |
AM0331 # 01 Y:1998 | 01 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $159,000 | $170,000 | Not Implemented |
AM0331 # 03 Y:1998 | 03 | 1998 | USE OPTIMUM TEMPERATURE | $3,360 | $0 | Implemented |
AM0331 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,880 | $5,500 | Not Implemented |
AM0331 # 05 Y:1998 | 05 | 1998 | DISCONNECT BALLASTS | $1,355 | $850 | Implemented |
AM0331 # 06 Y:1998 | 06 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $870 | $0 | Implemented |
AM0331 # 07 Y:1998 | 07 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $809 | $0 | Implemented |
AM0331 # 08 Y:1998 | 08 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $730 | $0 | Implemented |
AM0331 # 09 Y:1998 | 09 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $710 | $0 | Implemented |
AM0331 # 11 Y:1998 | 11 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $475 | $40 | Implemented |
TN0623 # 01 Y:1998 | 01 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $140,000 | $56,120 | Not Implemented |
TN0623 # 02 Y:1998 | 02 | 1998 | AVOID CONTAMINATION OF END PIECES AND REUSE AS FEED STOCK | $81,250 | $2,400 | Not Implemented |
TN0623 # 03 Y:1998 | 03 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $77,680 | $121,440 | Implemented |
TN0623 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $52,045 | $61,760 | Implemented |