Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
238
matching recommendationsSIC | 2673 | Bags: Plastics, Laminated, & Coated |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0240 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $670 | $835 | Implemented |
AM0240 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $640 | $1,960 | Implemented |
AM0240 # 08 Y:1995 | 08 | 1995 | USE SYNTHETIC LUBRICANT | $610 | $0 | Implemented |
AM0240 # 09 Y:1995 | 09 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $330 | $500 | Implemented |
AM0229 # 01 Y:1995 | 01 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $53,900 | $0 | Implemented |
AM0229 # 02 Y:1995 | 02 | 1995 | CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES | $32,000 | $42,000 | Implemented |
AM0229 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,760 | $570 | Implemented |
AM0229 # 06 Y:1995 | 06 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $200 | Implemented |
GT0538 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,230 | $2,500 | Implemented |
GT0538 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,570 | $18,880 | Implemented |
GT0538 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,370 | $4,860 | Implemented |
AM0205 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $14,843 | $23,805 | Implemented |
AM0205 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,830 | $0 | Implemented |
AM0205 # 03 Y:1994 | 03 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,430 | $0 | Implemented |
AM0205 # 04 Y:1994 | 04 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,170 | $630 | Implemented |
AM0205 # 05 Y:1994 | 05 | 1994 | INSULATE BARE EQUIPMENT | $3,660 | $1,890 | Implemented |
AM0205 # 07 Y:1994 | 07 | 1994 | INSULATE BARE EQUIPMENT | $2,800 | $490 | Implemented |
AM0205 # 08 Y:1994 | 08 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $590 | $80 | Implemented |
AM0205 # 09 Y:1994 | 09 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $433 | $0 | Implemented |
MO0113 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,170 | $836 | Implemented |
HO0025 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $330 | $320 | Implemented |
HO0025 # 02 Y:1992 | 02 | 1992 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,071 | $1,072 | Implemented |
HO0025 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,322 | $800 | Implemented |
KU0381 # 01 Y:1992 | 01 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,545 | $20 | Implemented |