Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 2674 | Bags: Uncoated Paper & Multiwall |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0491 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,820 | $4,110 | Not Implemented |
CO0491 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,740 | $570 | Implemented |
CO0491 # 04 Y:2001 | 04 | 2001 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $3,630 | $1,000 | Not Implemented |
CO0491 # 05 Y:2001 | 05 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,870 | $1,300 | Implemented |
CO0491 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $0 | Not Implemented |
CO0491 # 07 Y:2001 | 07 | 2001 | INSTALL OCCUPANCY SENSORS | $220 | $210 | Not Implemented |
CO0491 # 08 Y:2001 | 08 | 2001 | INSTALL BACK-UP EQUIPMENT | $54,170 | $84,380 | Implemented |
CO0491 # 01 Y:2001 | 01 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $20,780 | $61,010 | Implemented |
LL0121 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $593 | $495 | Implemented |
LL0121 # 05 Y:2001 | 05 | 2001 | PAY UTILITY BILLS ON TIME | $10,648 | $0 | Implemented |
LL0121 # 04 Y:2001 | 04 | 2001 | PAY UTILITY BILLS ON TIME | $3,665 | $0 | Implemented |
LL0121 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $4,301 | $15,406 | Not Implemented |
LL0121 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,365 | $2,160 | Implemented |
UF0277 # 15 Y:2001 | 15 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $540,000 | $0 | Not Implemented |
UF0277 # 14 Y:2001 | 14 | 2001 | INSTALL AUTOMATIC PACKING EQUIPMENT | $7,280 | $0 | Not Implemented |
UF0277 # 13 Y:2001 | 13 | 2001 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $7,281 | $0 | Implemented |
UF0277 # 12 Y:2001 | 12 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $9,600 | $0 | Not Implemented |
UF0277 # 11 Y:2001 | 11 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $2,712 | $0 | Implemented |
UF0277 # 10 Y:2001 | 10 | 2001 | INSTALL OCCUPANCY SENSORS | $1,315 | $0 | Not Implemented |
UF0277 # 09 Y:2001 | 09 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,962 | $0 | Not Implemented |
UF0277 # 08 Y:2001 | 08 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $8,088 | $0 | Implemented |
UF0277 # 07 Y:2001 | 07 | 2001 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,700 | $0 | Not Implemented |
UF0277 # 06 Y:2001 | 06 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,737 | $0 | Not Implemented |
UF0277 # 05 Y:2001 | 05 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,497 | $0 | Not Implemented |
UF0277 # 04 Y:2001 | 04 | 2001 | INSTALL SKYLIGHTS | $20,383 | $0 | Not Implemented |