IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

449

matching recommendations
Reset
SIC 2677 Envelopes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0276 # 01 Y:2001 01 2001 RECOVER WASTE HEAT FROM EQUIPMENT $7,091 $4,156 Not Implemented
IA0276 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,778 $194 Implemented
IA0276 # 03 Y:2001 03 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,246 $860 Implemented
IA0276 # 04 Y:2001 04 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $248 $25 Not Implemented
IA0276 # 05 Y:2001 05 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,758 $8,122 Implemented
IA0276 # 06 Y:2001 06 2001 RECOVER WASTE HEAT FROM EQUIPMENT $3,820 $4,156 Not Implemented
IA0276 # 07 Y:2001 07 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,964 $200 Implemented
IA0276 # 08 Y:2001 08 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,977 $0 Implemented
IA0276 # 09 Y:2001 09 2001 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $1,674 $4,000 Not Implemented
IA0276 # 10 Y:2001 10 2001 $16,120 $25,000 n/a
CO0477 # 01 Y:2000 01 2000 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $5,760 $15,500 Not Implemented
CO0477 # 02 Y:2000 02 2000 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,530 $2,000 Not Implemented
CO0477 # 03 Y:2000 03 2000 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,410 $970 Not Implemented
CO0477 # 04 Y:2000 04 2000 USE OPTIMUM TEMPERATURE $1,050 $200 Not Implemented
CO0477 # 05 Y:2000 05 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $450 $1,060 Not Implemented
CO0477 # 06 Y:2000 06 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $220 $150 Not Implemented
CO0477 # 07 Y:2000 07 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20 $0 Not Implemented
MS0137 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,259 $898 Implemented
MS0137 # 02 Y:1999 02 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,522 $660 Implemented
MS0137 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,249 $675 Not Implemented
MS0137 # 04 Y:1999 04 1999 USE PHOTOCELL CONTROLS $640 $463 Not Implemented
MS0137 # 05 Y:1999 05 1999 $135 $25 Implemented
MS0137 # 06 Y:1999 06 1999 $225,000 $252,938 Not Implemented
MO0228 # 01 Y:1998 01 1998 $2,820 $3,700 Implemented
MO0228 # 02 Y:1998 02 1998 $6,875 $9,000 Not Implemented