Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsSIC | 2679 | Converted Paper Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0294 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $10,219 | $4,900 | Not Implemented |
WV0294 # 10 Y:2004 | 10 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $232 | $129 | Not Implemented |
WV0294 # 09 Y:2004 | 09 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $609 | $46 | Implemented |
WV0294 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,317 | $215 | Implemented |
WV0294 # 07 Y:2004 | 07 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,431 | $784 | Implemented |
WV0294 # 06 Y:2004 | 06 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,472 | $920 | Implemented |
WV0294 # 05 Y:2004 | 05 | 2004 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $509,116 | $20,000 | Not Implemented |
WV0294 # 04 Y:2004 | 04 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,247 | $2,660 | Implemented |
WV0294 # 03 Y:2004 | 03 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $5,704 | $230 | Implemented |
WV0294 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,792 | $30,627 | Not Implemented |
LM0076 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $528 | $25 | Implemented |
LM0076 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,513 | $880 | Implemented |
LM0076 # 06 Y:2004 | 06 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,766 | $1,500 | Not Implemented |
LM0076 # 05 Y:2004 | 05 | 2004 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $6,736 | $2,500 | Implemented |
LM0076 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,953 | $3,825 | Not Implemented |
LM0076 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $255 | $281 | Implemented |
LM0076 # 02 Y:2004 | 02 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,952 | $1,300 | Implemented |