Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

419

matching recommendations
Reset
SIC 27 Printing And Publishing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0096 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,867 $12,220 Not Implemented
BD0096 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $2,223 $400 Not Implemented
BD0096 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,597 $800 Implemented
BD0096 # 05 Y:1997 05 1997 RECOVER WASTE HEAT FROM EQUIPMENT $1,363 $3,500 Not Implemented
BD0096 # 06 Y:1997 06 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,177 $2,086 Not Implemented
BD0096 # 07 Y:1997 07 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $301 $400 Implemented
BD0096 # 08 Y:1997 08 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $300 $300 Not Implemented
BD0096 # 09 Y:1997 09 1997 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $6,445 $8,600 Not Implemented
WI0276 # 01 Y:1996 01 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $4,740 $15,000 Not Implemented
WI0276 # 02 Y:1996 02 1996 REPLACE CLOTH RAGS WITH PAPER TOWELS $3,400 $0 Implemented
WI0276 # 03 Y:1996 03 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $2,454 $0 Not Implemented
WI0276 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,022 $2,144 Not Implemented
WI0276 # 05 Y:1996 05 1996 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $2,230 $0 Not Implemented
WI0276 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $1,122 $2,310 Not Implemented
WI0276 # 07 Y:1996 07 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $318 $1,380 Not Implemented
WI0276 # 08 Y:1996 08 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $440 $500 Implemented
WI0276 # 09 Y:1996 09 1996 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $404 $0 Not Implemented
WI0276 # 10 Y:1996 10 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $140 $0 Not Implemented
WI0274 # 01 Y:1996 01 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $8,100 $0 Not Implemented
WI0274 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,613 $1,400 Not Implemented
WI0274 # 03 Y:1996 03 1996 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $3,082 $10,500 Implemented
WI0274 # 04 Y:1996 04 1996 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,686 $0 Not Implemented
WI0274 # 05 Y:1996 05 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $905 $700 Implemented
WI0274 # 06 Y:1996 06 1996 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $748 $1,000 Implemented
WI0274 # 07 Y:1996 07 1996 INSTALL OCCUPANCY SENSORS $369 $900 Not Implemented