Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
419
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0096 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,867 | $12,220 | Not Implemented |
BD0096 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $2,223 | $400 | Not Implemented |
BD0096 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,597 | $800 | Implemented |
BD0096 # 05 Y:1997 | 05 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,363 | $3,500 | Not Implemented |
BD0096 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,177 | $2,086 | Not Implemented |
BD0096 # 07 Y:1997 | 07 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $301 | $400 | Implemented |
BD0096 # 08 Y:1997 | 08 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $300 | $300 | Not Implemented |
BD0096 # 09 Y:1997 | 09 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $6,445 | $8,600 | Not Implemented |
WI0276 # 01 Y:1996 | 01 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,740 | $15,000 | Not Implemented |
WI0276 # 02 Y:1996 | 02 | 1996 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $3,400 | $0 | Implemented |
WI0276 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,454 | $0 | Not Implemented |
WI0276 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,022 | $2,144 | Not Implemented |
WI0276 # 05 Y:1996 | 05 | 1996 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $2,230 | $0 | Not Implemented |
WI0276 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $1,122 | $2,310 | Not Implemented |
WI0276 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $318 | $1,380 | Not Implemented |
WI0276 # 08 Y:1996 | 08 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $440 | $500 | Implemented |
WI0276 # 09 Y:1996 | 09 | 1996 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $404 | $0 | Not Implemented |
WI0276 # 10 Y:1996 | 10 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $140 | $0 | Not Implemented |
WI0274 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $8,100 | $0 | Not Implemented |
WI0274 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,613 | $1,400 | Not Implemented |
WI0274 # 03 Y:1996 | 03 | 1996 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $3,082 | $10,500 | Implemented |
WI0274 # 04 Y:1996 | 04 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,686 | $0 | Not Implemented |
WI0274 # 05 Y:1996 | 05 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $905 | $700 | Implemented |
WI0274 # 06 Y:1996 | 06 | 1996 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $748 | $1,000 | Implemented |
WI0274 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $369 | $900 | Not Implemented |