Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
335
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0182 # 08 Y:1986 | 08 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $160 | $0 | Implemented |
KU0182 # 09 Y:1986 | 09 | 1986 | IMPROVE LUBRICATION PRACTICES | $6,002 | $4,500 | Implemented |
KU0162 # 01 Y:1985 | 01 | 1985 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,801 | $4,838 | Not Implemented |
KU0162 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $3,684 | $782 | Not Implemented |
KU0162 # 03 Y:1985 | 03 | 1985 | IMPROVE LUBRICATION PRACTICES | $5,315 | $2,000 | Not Implemented |
KU0162 # 04 Y:1985 | 04 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,058 | $3,000 | Not Implemented |
KU0162 # 05 Y:1985 | 05 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,210 | $4,973 | Not Implemented |
KU0162 # 06 Y:1985 | 06 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,763 | $47 | Not Implemented |
KU0162 # 07 Y:1985 | 07 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,074 | $7 | Not Implemented |
KU0162 # 08 Y:1985 | 08 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $395 | $0 | Not Implemented |
KU0162 # 09 Y:1985 | 09 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $405 | $700 | Not Implemented |
KU0162 # 10 Y:1985 | 10 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $594 | $500 | Not Implemented |
KU0162 # 11 Y:1985 | 11 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $391 | $150 | Not Implemented |
KU0146 # 01 Y:1984 | 01 | 1984 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $26,862 | $25,000 | Not Implemented |
KU0146 # 02 Y:1984 | 02 | 1984 | USE OPTIMUM THICKNESS INSULATION | $8,162 | $450 | Implemented |
KU0146 # 03 Y:1984 | 03 | 1984 | INSULATE BARE EQUIPMENT | $1,774 | $389 | Not Implemented |
KU0146 # 04 Y:1984 | 04 | 1984 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $540 | $600 | Not Implemented |
KU0146 # 05 Y:1984 | 05 | 1984 | IMPROVE LUBRICATION PRACTICES | $2,306 | $1,500 | Not Implemented |
KU0146 # 06 Y:1984 | 06 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,336 | $10,562 | Not Implemented |
KU0146 # 07 Y:1984 | 07 | 1984 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $8,653 | $75 | Implemented |
KU0146 # 08 Y:1984 | 08 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $17,085 | $12,000 | Implemented |
KU0146 # 09 Y:1984 | 09 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,806 | $3,000 | Not Implemented |
KU0146 # 10 Y:1984 | 10 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $345 | $137 | Implemented |
KU0146 # 11 Y:1984 | 11 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $636 | $25 | Implemented |
KU0146 # 12 Y:1984 | 12 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $200 | $275 | Implemented |