Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0136 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,098 | $535 | Implemented |
CO0138 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $470 | $200 | Implemented |
CO0138 # 02 Y:1988 | 02 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $536 | $2,000 | Not Implemented |
CO0138 # 03 Y:1988 | 03 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $996 | $510 | Not Implemented |
CO0138 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $127 | $0 | Implemented |
CO0138 # 05 Y:1988 | 05 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $130 | $0 | Implemented |
CO0138 # 06 Y:1988 | 06 | 1988 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,047 | $48 | Implemented |
CO0138 # 07 Y:1988 | 07 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,693 | $200 | Not Implemented |
CO0138 # 08 Y:1988 | 08 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,178 | $250 | Implemented |
CO0138 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $348 | $375 | Not Implemented |
CO0138 # 10 Y:1988 | 10 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,884 | $1,472 | Implemented |
UD0273 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,249 | $300 | Implemented |
UD0273 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,466 | $0 | Not Implemented |
UD0273 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $799 | $500 | Not Implemented |
UD0273 # 04 Y:1989 | 04 | 1989 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $10,928 | $28,000 | Implemented |
UD0273 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,844 | $15,120 | Not Implemented |
CO0134 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $211 | $200 | Not Implemented |
CO0134 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $790 | $1,162 | Implemented |
CO0134 # 03 Y:1988 | 03 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $455 | $421 | Implemented |
CO0134 # 04 Y:1988 | 04 | 1988 | INSTALL SET-BACK TIMERS | $779 | $800 | Not Implemented |
CO0134 # 05 Y:1988 | 05 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $167 | $300 | Not Implemented |
CO0134 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $445 | $674 | Implemented |
CO0132 # 01 Y:1988 | 01 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,251 | $250 | Implemented |
CO0132 # 02 Y:1988 | 02 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,629 | $250 | Not Implemented |
CO0132 # 03 Y:1988 | 03 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,170 | $600 | Implemented |