Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
219
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0508 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $600 | $0 | Not Implemented |
OK0508 # 01 Y:1996 | 01 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,243 | $620 | Implemented |
OK0497 # 01 Y:1996 | 01 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $9,000 | $0 | Implemented |
OK0497 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,269 | $4,587 | Not Implemented |
OK0497 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $1,213 | $396 | Not Implemented |
OK0497 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,106 | $1,965 | Not Implemented |
OK0497 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $187 | $50 | Implemented |
OK0488 # 01 Y:1996 | 01 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,288 | $8,400 | Implemented |
OK0488 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $125 | $0 | Not Implemented |
OK0488 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $64 | $30 | Implemented |
OK0488 # 04 Y:1996 | 04 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $501 | $2,964 | Implemented |
OK0488 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52 | $198 | Not Implemented |
OK0488 # 06 Y:1996 | 06 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $210 | $0 | Implemented |
OK0485 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,114 | $23,322 | Not Implemented |
OK0485 # 05 Y:1996 | 05 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,970 | $29,500 | Implemented |
OK0485 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $428 | $786 | Implemented |
OK0485 # 02 Y:1996 | 02 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,827 | $2,730 | Implemented |
OK0485 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $131 | $395 | Not Implemented |
OK0478 # 01 Y:1995 | 01 | 1995 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $63,653 | $25,000 | Implemented |
OK0478 # 02 Y:1995 | 02 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,374 | $48,000 | Implemented |
OK0478 # 03 Y:1995 | 03 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,482 | $2,520 | Not Implemented |
OK0478 # 04 Y:1995 | 04 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,490 | $2,500 | Not Implemented |
OK0478 # 05 Y:1995 | 05 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,792 | $160 | Not Implemented |
OK0478 # 09 Y:1995 | 09 | 1995 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $8,089 | $4,295 | Implemented |
OK0478 # 11 Y:1995 | 11 | 1995 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,300 | $0 | Implemented |