IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

129

matching recommendations
Reset
SIC 27 Printing And Publishing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0531 # 01 Y:1994 01 1994 INSTALL TIMERS AND/OR THERMOSTATS $4,142 $1,780 Not Implemented
TN0531 # 02 Y:1994 02 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,094 $4,300 Not Implemented
TN0531 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,941 $1,848 Implemented
TN0531 # 04 Y:1994 04 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $478 $0 Not Implemented
TN0531 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $169 $144 Not Implemented
TN0531 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $141 $430 Implemented
TN0531 # 07 Y:1994 07 1994 OPTIMIZE PLANT POWER FACTOR $300 $1,000 Not Implemented
TN0531 # 08 Y:1994 08 1994 PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS $18,313 $0 Not Implemented
TN0531 # 09 Y:1994 09 1994 RECYCLE WASTE INK AND CLEANUP SOLVENT $6,659 $0 Not Implemented
TN0531 # 10 Y:1994 10 1994 RECYCLE CLEANING SOLVENT AND REUSE $5,287 $17,300 Not Implemented
TN0419 # 01 Y:1991 01 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,626 $15,520 Not Implemented
TN0419 # 02 Y:1991 02 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,142 $5,600 Not Implemented
TN0419 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $2,007 $1,042 Not Implemented
TN0419 # 04 Y:1991 04 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,300 $1,760 Not Implemented
TN0419 # 05 Y:1991 05 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $618 $0 Not Implemented
TN0419 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $546 $517 Not Implemented
TN0419 # 07 Y:1991 07 1991 INSTALL SET-BACK TIMERS $417 $0 Not Implemented
TN0419 # 08 Y:1991 08 1991 OPTIMIZE PLANT POWER FACTOR $6,000 $10,000 Not Implemented
TN0255 # 01 Y:1985 01 1985 USE HEAT PUMP FOR SPACE CONDITIONING $1,340 $2,000 Not Implemented
TN0255 # 02 Y:1985 02 1985 INSTALL TIMERS AND/OR THERMOSTATS $1,207 $1,640 Implemented
TN0255 # 03 Y:1985 03 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $340 $250 Implemented
TN0255 # 04 Y:1985 04 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $255 $560 Not Implemented
TN0255 # 05 Y:1985 05 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $238 $265 Implemented
TN0255 # 06 Y:1985 06 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $119 $0 Not Implemented
TN0255 # 07 Y:1985 07 1985 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $51 $0 Implemented