Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
419
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0375 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $6,364 | $675 | Not Implemented |
WI0375 # 07 Y:2000 | 07 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,097 | $7,825 | Not Implemented |
WI0375 # 08 Y:2000 | 08 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,855 | $500 | Implemented |
WI0375 # 09 Y:2000 | 09 | 2000 | USE OPTIMUM THICKNESS INSULATION | $1,052 | $1,084 | Not Implemented |
WI0375 # 10 Y:2000 | 10 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $969 | $740 | Not Implemented |
WI0375 # 11 Y:2000 | 11 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $957 | $300 | Not Implemented |
WI0375 # 12 Y:2000 | 12 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $395 | $0 | Not Implemented |
WI0372 # 01 Y:2000 | 01 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $201,600 | $0 | Not Implemented |
WI0372 # 02 Y:2000 | 02 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $36,000 | $0 | Not Implemented |
WI0372 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,349 | $13,911 | Not Implemented |
WI0372 # 04 Y:2000 | 04 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,060 | $0 | Not Implemented |
WI0372 # 05 Y:2000 | 05 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,804 | $2,000 | Not Implemented |
WI0372 # 06 Y:2000 | 06 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,632 | $0 | Not Implemented |
WI0372 # 07 Y:2000 | 07 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $737 | $640 | Not Implemented |
WI0372 # 08 Y:2000 | 08 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $137 | $400 | Not Implemented |
WI0371 # 01 Y:2000 | 01 | 2000 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $24,407 | $25,200 | Not Implemented |
WI0371 # 02 Y:2000 | 02 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,743 | $0 | Implemented |
WI0371 # 03 Y:2000 | 03 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,046 | $1,000 | Not Implemented |
WI0371 # 04 Y:2000 | 04 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,684 | $0 | Implemented |
WI0371 # 05 Y:2000 | 05 | 2000 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $7,221 | $0 | Not Implemented |
WI0371 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $2,725 | $7,200 | Not Implemented |
WI0371 # 07 Y:2000 | 07 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,030 | $6,090 | Not Implemented |
WI0371 # 08 Y:2000 | 08 | 2000 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,686 | $3,150 | Not Implemented |
WI0371 # 09 Y:2000 | 09 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $602 | $740 | Not Implemented |
WI0371 # 10 Y:2000 | 10 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $370 | $0 | Implemented |