Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
260
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0584 # 01 Y:1999 | 01 | 1999 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $28,107 | $3,150 | Implemented |
UD0584 # 02 Y:1999 | 02 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $998 | $1,200 | Implemented |
UD0584 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $981 | $356 | Implemented |
UM0107 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,746 | $3,572 | Not Implemented |
UM0107 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $250 | $250 | Not Implemented |
UM0107 # 03 Y:1998 | 03 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,179 | $250 | Not Implemented |
UM0107 # 04 Y:1998 | 04 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $130 | $100 | Not Implemented |
UM0107 # 05 Y:1998 | 05 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $10,400 | $2,250 | Not Implemented |
UM0107 # 06 Y:1998 | 06 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $14,550 | $5,200 | Not Implemented |
UD0526 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $14,725 | $15,000 | Implemented |
UD0526 # 02 Y:1997 | 02 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,197 | $5,000 | Implemented |
UD0526 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,181 | $11,751 | Implemented |
UD0524 # 01 Y:1997 | 01 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,145 | $0 | Implemented |
UD0524 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $1,914 | $9,400 | Implemented |
UD0524 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,568 | $0 | Not Implemented |
UD0524 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,898 | $16,158 | Implemented |
UD0524 # 05 Y:1997 | 05 | 1997 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $5,400 | $22,500 | Implemented |
UD0503 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,355 | $4,000 | Implemented |
UD0503 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,164 | $12,748 | Not Implemented |
UD0503 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $-368 | $10,000 | Implemented |
UD0503 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $449 | $500 | Not Implemented |
UD0503 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,143 | $31,020 | Implemented |
UD0503 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,120 | $600 | Implemented |
UD0503 # 07 Y:1996 | 07 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,772 | $500 | Implemented |
UD0503 # 08 Y:1996 | 08 | 1996 | PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) | $28,200 | $0 | Implemented |