Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
260
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0311 # 04 Y:1990 | 04 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,107 | $6,000 | Not Implemented |
UD0309 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,076 | $18,000 | Not Implemented |
UD0309 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,951 | $700 | Implemented |
UD0309 # 03 Y:1990 | 03 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $1,295 | $200 | Implemented |
UD0309 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,374 | $8,000 | Not Implemented |
UD0309 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $900 | $500 | Not Implemented |
UD0309 # 06 Y:1990 | 06 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,028 | $10,000 | Implemented |
UD0310 # 01 Y:1990 | 01 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,258 | $0 | Not Implemented |
UD0310 # 02 Y:1990 | 02 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $862 | $0 | Implemented |
UD0310 # 03 Y:1990 | 03 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $170 | $0 | Implemented |
UD0310 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $442 | Implemented |
UD0310 # 05 Y:1990 | 05 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $907 | $1,800 | Implemented |
UD0310 # 06 Y:1990 | 06 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,867 | $25,000 | Not Implemented |
UD0298 # 01 Y:1989 | 01 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $979 | $2,250 | Implemented |
UD0298 # 02 Y:1989 | 02 | 1989 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,921 | $1,500 | Not Implemented |
UD0273 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,249 | $300 | Implemented |
UD0273 # 02 Y:1989 | 02 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,466 | $0 | Not Implemented |
UD0273 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $799 | $500 | Not Implemented |
UD0273 # 04 Y:1989 | 04 | 1989 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $10,928 | $28,000 | Implemented |
UD0273 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,844 | $15,120 | Not Implemented |
UD0268 # 01 Y:1988 | 01 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,113 | $0 | Implemented |
UD0268 # 02 Y:1988 | 02 | 1988 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $3,128 | $3,448 | Implemented |
UD0268 # 03 Y:1988 | 03 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,096 | $3,000 | Implemented |
UD0268 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $281 | $0 | Implemented |
UD0258 # 01 Y:1988 | 01 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,392 | $0 | Not Implemented |