ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0274 # 06 Y:1996 | 06 | 1996 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $748 | $1,000 | Implemented |
WI0274 # 05 Y:1996 | 05 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $905 | $700 | Implemented |
WI0274 # 08 Y:1996 | 08 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $331 | $640 | Implemented |
WI0274 # 04 Y:1996 | 04 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,686 | $0 | Not Implemented |
WI0274 # 03 Y:1996 | 03 | 1996 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $3,082 | $10,500 | Implemented |
WI0274 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $369 | $900 | Not Implemented |
WI0274 # 02 Y:1996 | 02 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,613 | $1,400 | Not Implemented |
WI0274 # 01 Y:1996 | 01 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $8,100 | $0 | Not Implemented |
BD0036 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,238 | $54,640 | Implemented |
BD0036 # 07 Y:1995 | 07 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,059 | $2,250 | Not Implemented |
BD0036 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,102 | $6,784 | Implemented |
BD0036 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $5,009 | $825 | Implemented |
BD0036 # 04 Y:1995 | 04 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,847 | $5,000 | Not Implemented |
BD0036 # 03 Y:1995 | 03 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,970 | $1,575 | Implemented |
BD0036 # 02 Y:1995 | 02 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $23,437 | $12,950 | Implemented |
WI0223 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $332 | $640 | Not Implemented |
WI0223 # 05 Y:1994 | 05 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $816 | $0 | Implemented |
WI0223 # 04 Y:1994 | 04 | 1994 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $1,910 | $0 | Implemented |
WI0223 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $228 | $225 | Not Implemented |
WI0223 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,412 | $2,989 | Not Implemented |
WI0223 # 01 Y:1994 | 01 | 1994 | REPLACE BOILER | $3,696 | $6,500 | Not Implemented |
WI0157 # 01 Y:1992 | 01 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,838 | $3,915 | Not Implemented |
WI0157 # 06 Y:1992 | 06 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $600 | $640 | Not Implemented |
WI0157 # 05 Y:1992 | 05 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,537 | $1,300 | Not Implemented |
WI0157 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,382 | $7 | Not Implemented |