IAC logo
IAC Assessment: WI0157
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0157
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1992
Principal Product PRINTING/BINDING BOOKS
NAICS n/a
SIC 2731 - Book Publishing
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 5,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $252,157 3,128,077 kWh $0.08
Fuel Oil #2 $50,726 9,015 MMBtu $5.63
TOTAL ENERGY COSTS $302,883
RECOMMENDED SAVINGS* $16,152 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,601
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$6,838
Cost:
$3,915
$6,838 84,994 - - - - $6,838
84,994
kWh
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,003
Cost:
-
$1,003 12,603 - - - - $1,003
12,603
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,382
Cost:
$7
$3,863 47,773 - - $(-481) - $3,863
47,773
kWh
-
-
MMBtu
$(-481)
-
$
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,601
Cost:
-
$2,601 - - - - - $2,601
-
kWh
-
-
MMBtu
-
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,537
Cost:
$1,300
- - $1,537 413 - - -
-
kWh
$1,537
413
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$600
Cost:
$640
$600 7,327 - - - - $600
7,327
kWh
-
-
MMBtu
-
-
$
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$191
Cost:
$178
$191 2,345 - - - - $191
2,345
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$16,152
Cost:
$6,040
$15,096 155,042 $1,537 413 $(-481) - $15,096
155,042
kWh
$1,537
413
MMBtu
$(-481)
-
$
TOTAL IMPLEMENTED Savings:
$2,601
Cost:
-
$2,601 - - - - - $2,601
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes