Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 273 Books
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0305 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $81,866 $60,000 Not Implemented
LE0305 # 02 Y:2010 02 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $47,762 $17,000 Not Implemented
LE0305 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $28,242 $1,720 Not Implemented
LE0305 # 04 Y:2010 04 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $27,533 $0 Not Implemented
LE0305 # 05 Y:2010 05 2010 INSTALL TIMERS AND/OR THERMOSTATS $15,838 $250 Not Implemented
LE0305 # 06 Y:2010 06 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,566 $35,000 Not Implemented
LE0305 # 07 Y:2010 07 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,857 $0 Not Implemented
LE0305 # 08 Y:2010 08 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,426 $2,800 Not Implemented
LE0305 # 09 Y:2010 09 2010 INSTALL OCCUPANCY SENSORS $3,000 $900 Not Implemented
WV0402 # 01 Y:2010 01 2010 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $63,671 $114,000 Not Implemented
WV0402 # 02 Y:2010 02 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $32,843 $25,000 Not Implemented
WV0402 # 03 Y:2010 03 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,488 $0 Implemented
WV0402 # 04 Y:2010 04 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,346 $9,200 Implemented
WV0402 # 05 Y:2010 05 2010 RECOVER WASTE HEAT FROM EQUIPMENT $13,296 $2,000 Not Implemented
WV0402 # 06 Y:2010 06 2010 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $12,095 $4,000 Not Implemented
WV0402 # 07 Y:2010 07 2010 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,390 $0 Implemented