Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,451
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0027 # 08 Y:1988 | 08 | 1988 | OPTIMIZE PLANT POWER FACTOR | $1,092 | $2,730 | Implemented |
OR0027 # 09 Y:1988 | 09 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,684 | $7,740 | Implemented |
OR0027 # 10 Y:1988 | 10 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31 | $135 | Implemented |
KU0251 # 03 Y:1988 | 03 | 1988 | IMPROVE LUBRICATION PRACTICES | $530 | $0 | Implemented |
KU0251 # 06 Y:1988 | 06 | 1988 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $209 | $0 | Implemented |
KU0251 # 07 Y:1988 | 07 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $173 | $0 | Implemented |
KU0251 # 08 Y:1988 | 08 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $187 | $0 | Implemented |
KU0251 # 09 Y:1988 | 09 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $133 | $0 | Implemented |
RU0022 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,410 | $252 | Implemented |
RU0022 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $306 | $0 | Implemented |
RU0022 # 05 Y:1988 | 05 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,352 | $1,575 | Implemented |
RU0022 # 06 Y:1988 | 06 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $651 | $717 | Implemented |
WI0022 # 01 Y:1988 | 01 | 1988 | IMPROVE LUBRICATION PRACTICES | $9,403 | $0 | Implemented |
WI0022 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,715 | $0 | Implemented |
WI0022 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,405 | $196 | Implemented |
WI0022 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $220 | $500 | Implemented |
WI0022 # 05 Y:1988 | 05 | 1988 | AIR CONDITION ONLY SPACE NECESSARY | $1,625 | $2,500 | Implemented |
AM0010 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,314 | $177 | Implemented |
AM0010 # 03 Y:1987 | 03 | 1987 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,886 | $2,394 | Implemented |
AM0010 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $835 | $689 | Implemented |
KU0229 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,296 | $6,510 | Implemented |
KU0229 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $1,678 | $8,000 | Implemented |
KU0229 # 06 Y:1987 | 06 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $672 | $0 | Implemented |
RU0006 # 01 Y:1987 | 01 | 1987 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,140 | $396 | Implemented |
RU0006 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,672 | $0 | Implemented |