IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,301

matching recommendations
Reset
SIC 275 Commercial Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0070 # 01 Y:1983 01 1983 REDUCE VENTILATION AIR $68,280 $2,361 Not Implemented
KU0070 # 02 Y:1983 02 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,139 $1,900 Not Implemented
KU0070 # 03 Y:1983 03 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $8,631 $5,200 Not Implemented
KU0070 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,046 $3,942 Not Implemented
KU0070 # 05 Y:1983 05 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,975 $13,000 Implemented
KU0070 # 06 Y:1983 06 1983 OPTIMIZE PLANT POWER FACTOR $3,510 $5,820 Not Implemented
KU0070 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $664 $42 Implemented
KU0070 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $615 $0 Not Implemented
KU0070 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $502 $72 Not Implemented
UD0076 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,494 $421 Not Implemented
UD0076 # 02 Y:1983 02 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $427 $250 Not Implemented
UD0076 # 03 Y:1983 03 1983 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $990 $438 Not Implemented
UD0075 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,287 $562 Not Implemented
UD0075 # 02 Y:1983 02 1983 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $41,500 $80,000 Not Implemented
UD0075 # 03 Y:1983 03 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,692 $0 Not Implemented
UD0075 # 04 Y:1983 04 1983 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING $4,855 $17,600 Not Implemented
UD0075 # 05 Y:1983 05 1983 TURN OFF EQUIPMENT WHEN NOT IN USE $4,046 $33,000 Not Implemented
UD0075 # 06 Y:1983 06 1983 TURN OFF EQUIPMENT WHEN NOT IN USE $3,168 $400 Not Implemented
UD0073 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,488 $150 Not Implemented
UD0073 # 02 Y:1983 02 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,396 $37,500 Not Implemented
UD0073 # 03 Y:1983 03 1983 AIR CONDITION ONLY SPACE NECESSARY $356 $375 Not Implemented
OK0070 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,791 $60 Implemented
OK0070 # 02 Y:1983 02 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $297 $392 Implemented
OK0070 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $163 $475 Not Implemented
OK0070 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $197 $475 Not Implemented