Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,301
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0127 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,954 | $5,472 | Implemented |
OD0127 # 02 Y:1999 | 02 | 1999 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $477 | $80 | Not Implemented |
OD0127 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,582 | $240 | Implemented |
OD0127 # 04 Y:1999 | 04 | 1999 | COMBINE UTILITY METERS | $9,570 | $5,000 | Implemented |
SF0157 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $1,834 | $1,456 | Implemented |
SF0157 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,418 | $45,400 | Implemented |
SF0157 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $396 | $2,106 | Implemented |
SF0157 # 04 Y:1999 | 04 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,602 | $0 | Not Implemented |
SF0157 # 05 Y:1999 | 05 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $960 | $250 | Implemented |
SF0157 # 06 Y:1999 | 06 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $19,132 | $49,350 | Not Implemented |
SF0157 # 07 Y:1999 | 07 | 1999 | ADOPT IN-HOUSE MATERIAL GENERATION | $78,960 | $30,000 | Not Implemented |
UF0211 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,004 | $7,226 | Implemented |
UF0211 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,672 | $1,458 | Implemented |
UF0211 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,742 | $3,800 | Implemented |
UF0211 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,779 | $0 | Implemented |
UF0211 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,297 | $750 | Implemented |
UF0211 # 06 Y:1998 | 06 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,188 | $642 | Not Implemented |
UF0211 # 07 Y:1998 | 07 | 1998 | OPTIMIZE PLANT POWER FACTOR | $1,623 | $5,000 | Not Implemented |
UF0211 # 08 Y:1998 | 08 | 1998 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $14,651 | $28,996 | Not Implemented |
UF0211 # 09 Y:1998 | 09 | 1998 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,843 | $1,500 | Not Implemented |
UF0211 # 10 Y:1998 | 10 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,727 | $0 | Implemented |
UF0211 # 11 Y:1998 | 11 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $39,900 | $123,000 | Implemented |
UF0211 # 12 Y:1998 | 12 | 1998 | APPLY FOR INVESTMENT INCENTIVES | $36,605 | $50 | Not Implemented |
UF0211 # 13 Y:1998 | 13 | 1998 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $172,000 | $150,000 | Implemented |
NC0145 # 01 Y:1998 | 01 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,611 | $25,000 | Not Implemented |