Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0256 # 05 Y:2022 | 05 | 2022 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $8,266 | $1,440 | Not Implemented |
UA0256 # 04 Y:2022 | 04 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,976 | $5,978 | Implemented |
UA0256 # 03 Y:2022 | 03 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,671 | $1,000 | Implemented |
UA0256 # 02 Y:2022 | 02 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $241 | $540 | Not Implemented |
UA0256 # 01 Y:2022 | 01 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,430 | $1,362 | Not Implemented |
UA0109 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,846 | $46,099 | Implemented |
UA0109 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $3,107 | $5,850 | Implemented |
UA0109 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,609 | $4,160 | Not Implemented |
UA0109 # 04 Y:2013 | 04 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $3,494 | $0 | Not Implemented |
UA0056 # 02 Y:2010 | 02 | 2010 | USE PHOTOCELL CONTROLS | $451 | $900 | Implemented |
UA0056 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,084 | $640 | Not Implemented |
UA0056 # 05 Y:2010 | 05 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,045 | $240 | Implemented |
UA0056 # 04 Y:2010 | 04 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $5,615 | $2,000 | Implemented |
UA0056 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,865 | $38,883 | Implemented |
MS0094 # 03 Y:1997 | 03 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $226 | $0 | Implemented |
MS0094 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $668 | $2,014 | Not Implemented |
MS0094 # 04 Y:1997 | 04 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $578 | $3,500 | Not Implemented |
MS0094 # 01 Y:1997 | 01 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $674 | $498 | Implemented |
MS0094 # 05 Y:1997 | 05 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,000 | $21,264 | Implemented |
GT0585 # 06 Y:1996 | 06 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,520 | $9,000 | Not Implemented |
GT0585 # 07 Y:1996 | 07 | 1996 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $12,700 | $27,000 | Not Implemented |
GT0585 # 08 Y:1996 | 08 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $65,150 | $150,000 | Implemented |
GT0585 # 09 Y:1996 | 09 | 1996 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $11,350 | $20,000 | Not Implemented |
GT0585 # 05 Y:1996 | 05 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,363 | $74,200 | Not Implemented |
GT0585 # 02 Y:1996 | 02 | 1996 | OPTIMIZE PLANT POWER FACTOR | $33,556 | $59,500 | Implemented |