Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
86
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0092 # 01 Y:2005 | 01 | 2005 | USE SOY OR WATER-BASED INKS | $28,070 | $20,000 | Not Implemented |
UU0092 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,250 | $19,000 | Not Implemented |
UU0092 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,083 | $3,270 | Not Implemented |
UU0092 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $740 | $280 | Not Implemented |
UU0092 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $1,130 | $1,800 | Not Implemented |
UD0731 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,198 | $0 | Not Implemented |
UD0731 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,894 | $0 | Implemented |
UD0731 # 11 Y:2005 | 11 | 2005 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $4,182 | $0 | Not Implemented |
UD0731 # 12 Y:2005 | 12 | 2005 | REDUCE VENTILATION AIR | $1,932 | $119 | Not Implemented |
UD0731 # 16 Y:2005 | 16 | 2005 | DISCONNECT BALLASTS | $440 | $66 | Not Implemented |
UD0731 # 14 Y:2005 | 14 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,010 | $0 | Implemented |
UD0731 # 09 Y:2005 | 09 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,841 | $0 | Implemented |
UD0731 # 15 Y:2005 | 15 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $622 | $0 | Implemented |
UD0731 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,953 | $15,113 | Implemented |
UD0731 # 08 Y:2005 | 08 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $9,619 | $520 | Not Implemented |
UD0731 # 01 Y:2005 | 01 | 2005 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $54,200 | $60,000 | Implemented |
UD0731 # 05 Y:2005 | 05 | 2005 | CONDENSE OPERATION INTO ONE BUILDING | $13,200 | $0 | Not Implemented |
UD0731 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,130 | $0 | Not Implemented |
UD0731 # 02 Y:2005 | 02 | 2005 | CONDENSE OPERATION INTO ONE BUILDING | $28,800 | $0 | Not Implemented |
UD0731 # 03 Y:2005 | 03 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $24,427 | $0 | Not Implemented |
UD0731 # 07 Y:2005 | 07 | 2005 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $12,378 | $0 | Implemented |
UU0091 # 04 Y:2005 | 04 | 2005 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $250 | $75 | Not Implemented |
UU0091 # 02 Y:2005 | 02 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,360 | $420 | Not Implemented |
UU0091 # 05 Y:2005 | 05 | 2005 | OPTIMIZE PLANT POWER FACTOR | $12,500 | $15,290 | Not Implemented |
UU0091 # 01 Y:2005 | 01 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,270 | $7,000 | Not Implemented |