Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
176
matching recommendationsSIC | 2754 | Commercial Printing, Gravure |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1710 # 10 Y:2017 | 10 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $2,600 | $5,000 | Implemented |
UK1710 # 11 Y:2017 | 11 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,338 | $5,754 | Not Implemented |
UK1710 # 06 Y:2017 | 06 | 2017 | OPTIMIZE PLANT POWER FACTOR | $8,180 | $18,216 | Not Implemented |
UK1710 # 08 Y:2017 | 08 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,080 | $0 | Not Implemented |
DL0177 # 03 Y:2017 | 03 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $12,079 | $3,000 | Not Implemented |
DL0177 # 01 Y:2017 | 01 | 2017 | OPERATE BOILERS ON HIGH FIRE SETTING | $16,174 | $28,750 | Not Implemented |
DL0177 # 02 Y:2017 | 02 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,881 | $2,032 | Not Implemented |
DL0177 # 04 Y:2017 | 04 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $39,860 | $40,000 | Not Implemented |
LE0442 # 02 Y:2017 | 02 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,680 | $5,000 | Not Implemented |
LE0442 # 06 Y:2017 | 06 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,186 | $5,500 | Implemented |
LE0442 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $360 | $1,800 | Implemented |
LE0442 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,108 | $5,000 | Not Implemented |
LE0442 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,763 | $2,250 | Not Implemented |
LE0442 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,716 | $1,000 | Implemented |
LE0442 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,887 | $7,663 | Implemented |
OK0920 # 12 Y:2015 | 12 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,000 | $65,000 | Not Implemented |
OK0920 # 11 Y:2015 | 11 | 2015 | OPTIMIZE PLANT POWER FACTOR | $3,157 | $20,000 | Not Implemented |
OK0920 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,980 | $1,500 | Not Implemented |
OK0920 # 09 Y:2015 | 09 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $15,138 | $18,243 | Not Implemented |
OK0920 # 03 Y:2015 | 03 | 2015 | INSTALL SET-BACK TIMERS | $2,270 | $1,550 | Not Implemented |
OK0920 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,921 | $2,360 | Not Implemented |
OK0920 # 08 Y:2015 | 08 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,051 | $0 | Not Implemented |
OK0920 # 04 Y:2015 | 04 | 2015 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $820 | $3,450 | Not Implemented |
OK0920 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,796 | $15,971 | Not Implemented |
OK0920 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,190 | $5,218 | Not Implemented |