Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

176

matching recommendations
Reset
SIC 2754 Commercial Printing, Gravure
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1710 # 10 Y:2017 10 2017 UPGRADE CONTROLS ON COMPRESSORS $2,600 $5,000 Implemented
UK1710 # 11 Y:2017 11 2017 RECOVER WASTE HEAT FROM EQUIPMENT $4,338 $5,754 Not Implemented
UK1710 # 06 Y:2017 06 2017 OPTIMIZE PLANT POWER FACTOR $8,180 $18,216 Not Implemented
UK1710 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,080 $0 Not Implemented
DL0177 # 03 Y:2017 03 2017 REPAIR AND ELIMINATE STEAM LEAKS $12,079 $3,000 Not Implemented
DL0177 # 01 Y:2017 01 2017 OPERATE BOILERS ON HIGH FIRE SETTING $16,174 $28,750 Not Implemented
DL0177 # 02 Y:2017 02 2017 INSTALL / REPAIR INSULATION ON STEAM LINES $10,881 $2,032 Not Implemented
DL0177 # 04 Y:2017 04 2017 INSTALL / REPAIR INSULATION ON STEAM LINES $39,860 $40,000 Not Implemented
LE0442 # 02 Y:2017 02 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,680 $5,000 Not Implemented
LE0442 # 06 Y:2017 06 2017 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,186 $5,500 Implemented
LE0442 # 07 Y:2017 07 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $360 $1,800 Implemented
LE0442 # 05 Y:2017 05 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,108 $5,000 Not Implemented
LE0442 # 03 Y:2017 03 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,763 $2,250 Not Implemented
LE0442 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,716 $1,000 Implemented
LE0442 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,887 $7,663 Implemented
OK0920 # 12 Y:2015 12 2015 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $20,000 $65,000 Not Implemented
OK0920 # 11 Y:2015 11 2015 OPTIMIZE PLANT POWER FACTOR $3,157 $20,000 Not Implemented
OK0920 # 10 Y:2015 10 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,980 $1,500 Not Implemented
OK0920 # 09 Y:2015 09 2015 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,138 $18,243 Not Implemented
OK0920 # 03 Y:2015 03 2015 INSTALL SET-BACK TIMERS $2,270 $1,550 Not Implemented
OK0920 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,921 $2,360 Not Implemented
OK0920 # 08 Y:2015 08 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,051 $0 Not Implemented
OK0920 # 04 Y:2015 04 2015 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $820 $3,450 Not Implemented
OK0920 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,796 $15,971 Not Implemented
OK0920 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $5,218 Not Implemented