IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,202

matching recommendations
Reset
SIC 2759 Commercial Printing, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0127 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $757 $767 Implemented
SF0127 # 04 Y:1997 04 1997 INSTALL OCCUPANCY SENSORS $824 $2,025 Implemented
SF0127 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,884 $0 Implemented
SF0127 # 06 Y:1997 06 1997 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $309 $327 Implemented
SF0127 # 07 Y:1997 07 1997 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $296 $920 Not Implemented
SF0127 # 08 Y:1997 08 1997 OPTIMIZE PLANT POWER FACTOR $1,969 $3,215 Not Implemented
SF0127 # 09 Y:1997 09 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,606 $1,256 Not Implemented
SF0127 # 10 Y:1997 10 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,485 $15 Implemented
SF0127 # 11 Y:1997 11 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,726 $0 Implemented
SF0127 # 12 Y:1997 12 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,574 $0 Implemented
SF0127 # 13 Y:1997 13 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $17,820 $8,275 Implemented
SF0127 # 14 Y:1997 14 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $3,000 $150 Implemented
SF0127 # 15 Y:1997 15 1997 REDUCE SCRAP PRODUCTION $1,225 $1,000 Implemented
SF0127 # 16 Y:1997 16 1997 MINIMIZE WATER USAGE $901 $1,357 Not Implemented
SF0127 # 17 Y:1997 17 1997 MOVE PRODUCT USING MECHANICAL MEANS $10,920 $30,000 Implemented
KU0478 # 01 Y:1997 01 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,110 $58,000 Not Implemented
KU0478 # 02 Y:1997 02 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,330 $330 Implemented
KU0478 # 03 Y:1997 03 1997 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,130 $0 Not Implemented
KU0478 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $730 $170 Implemented
KU0478 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $500 $780 Not Implemented
KU0478 # 06 Y:1997 06 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $290 $1,050 Implemented
KU0478 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $190 $400 Not Implemented
KU0478 # 08 Y:1997 08 1997 RECYCLE WASTE INK AND CLEANUP SOLVENT $3,000 $0 Implemented
MS0094 # 01 Y:1997 01 1997 INSTALL TIMERS AND/OR THERMOSTATS $674 $498 Implemented
MS0094 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $668 $2,014 Not Implemented