Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,202

matching recommendations
Reset
SIC 2759 Commercial Printing, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0111 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $1,150 $1,540 Not Implemented
SF0111 # 06 Y:1997 06 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,765 $500 Not Implemented
UL0176 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $802 $1,661 Implemented
UL0176 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $136 $3,180 Not Implemented
UL0176 # 03 Y:1997 03 1997 RECYCLE WASTE INK AND CLEANUP SOLVENT $45,321 $0 Not Implemented
UL0176 # 04 Y:1997 04 1997 PURCHASE EQUIPMENT INSTEAD OF LEASING $11,180 $4,500 Not Implemented
UL0176 # 05 Y:1997 05 1997 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $9,373 $400 Not Implemented
UL0176 # 06 Y:1997 06 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $355,776 $77,600 Not Implemented
KG0080 # 01 Y:1997 01 1997 INSTALL TIMERS AND/OR THERMOSTATS $6,790 $150 n/a
KG0080 # 02 Y:1997 02 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $5,869 $500 n/a
KG0080 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,024 $7,350 n/a
KG0080 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,637 $684 n/a
KG0080 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $939 $25 n/a
KG0080 # 06 Y:1997 06 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,537 $0 n/a
KG0080 # 07 Y:1997 07 1997 MINIMIZE WATER USAGE $1,296 $371 n/a
KG0080 # 08 Y:1997 08 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $36,620 $3,000 n/a
KG0080 # 09 Y:1997 09 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $40,917 $7,500 n/a
DS0066 # 01 Y:1996 01 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $21,792 $21,193 Implemented
DS0066 # 02 Y:1996 02 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $27,874 $37,150 Not Implemented
DS0066 # 03 Y:1996 03 1996 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $28,580 $52,000 Implemented
DS0066 # 04 Y:1996 04 1996 METER WASTE WATER $1,464 $550 Not Implemented
UM0059 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,539 $1,680 Implemented
UM0059 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,494 $15,062 Implemented
UM0059 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $710 $1,200 Implemented
UM0059 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $973 $74 Implemented