Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
SIC 2759 Commercial Printing, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0176 # 06 Y:1997 06 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $355,776 $77,600 Not Implemented
UL0176 # 05 Y:1997 05 1997 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $9,373 $400 Not Implemented
UL0176 # 04 Y:1997 04 1997 PURCHASE EQUIPMENT INSTEAD OF LEASING $11,180 $4,500 Not Implemented
UL0176 # 03 Y:1997 03 1997 RECYCLE WASTE INK AND CLEANUP SOLVENT $45,321 $0 Not Implemented
UL0176 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $136 $3,180 Not Implemented
UL0176 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $802 $1,661 Implemented
UL0140 # 02 Y:1995 02 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $191 $20 Implemented
UL0140 # 07 Y:1995 07 1995 SELL USED PLATES TO AN ALUMINUM RECYCLER $40 $75 Not Implemented
UL0140 # 06 Y:1995 06 1995 RECYCLE WASTE INK AND CLEANUP SOLVENT $10,120 $0 Not Implemented
UL0140 # 05 Y:1995 05 1995 RECYCLE WASTE INK AND CLEANUP SOLVENT $5,575 $11,265 Not Implemented
UL0140 # 04 Y:1995 04 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,678 $0 Implemented
UL0140 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,580 $2,038 Implemented
UL0140 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,583 $50 Not Implemented
UD0436 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $533 $518 Not Implemented
UD0436 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,299 $15,139 Implemented
UD0436 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $4,381 $7,000 Implemented
UD0436 # 02 Y:1994 02 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,122 $0 Not Implemented
UD0436 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $11,729 $21,000 Implemented
UD0433 # 01 Y:1994 01 1994 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $6,342 $20,000 Not Implemented
UD0433 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,315 $1,950 Implemented
UD0433 # 04 Y:1994 04 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,093 $2,500 Not Implemented
UD0433 # 03 Y:1994 03 1994 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $2,059 $300 Implemented
UD0433 # 02 Y:1994 02 1994 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $4,410 $0 Implemented