Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
825
matching recommendationsSIC | 2759 | Commercial Printing, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0437 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,443 | $4,200 | Not Implemented |
UF0437 # 04 Y:2010 | 04 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $457 | $0 | Not Implemented |
UF0437 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,562 | $5,039 | Not Implemented |
UF0437 # 08 Y:2010 | 08 | 2010 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,387 | $1,200 | Not Implemented |
UF0437 # 02 Y:2010 | 02 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,263 | $4,600 | Not Implemented |
UF0437 # 09 Y:2010 | 09 | 2010 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $4,523 | $0 | Not Implemented |
UF0437 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,608 | $469 | Not Implemented |
UF0437 # 01 Y:2010 | 01 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $7,679 | $4,000 | Not Implemented |
UF0437 # 07 Y:2010 | 07 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $4,197 | $1,979 | Not Implemented |
DL0051 # 07 Y:2010 | 07 | 2010 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,473 | $3,840 | Not Implemented |
DL0051 # 03 Y:2010 | 03 | 2010 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $940 | $30 | Implemented |
DL0051 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,500 | $100 | Implemented |
DL0051 # 01 Y:2010 | 01 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,124 | $0 | Implemented |
DL0051 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,720 | $20,796 | Not Implemented |
DL0051 # 06 Y:2010 | 06 | 2010 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $4,250 | $960 | Not Implemented |
DL0051 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $573 | $0 | Implemented |
DL0051 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $150 | Not Implemented |
DL0051 # 09 Y:2010 | 09 | 2010 | REPLACE BOILER | $6,600 | $16,743 | Implemented |
MZ0039 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22,863 | $0 | Implemented |
MZ0039 # 02 Y:2009 | 02 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,294 | $8,400 | Implemented |
MZ0039 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $840 | $850 | Implemented |
MZ0039 # 05 Y:2009 | 05 | 2009 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $15,679 | $18,600 | Implemented |
MZ0039 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $48,883 | $510,446 | Implemented |
WV0392 # 02 Y:2009 | 02 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,132 | $1,667 | Implemented |
WV0392 # 11 Y:2009 | 11 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $416 | $283 | Implemented |